Advanced search
Start date
Betweenand

Microemulsification in Analytical Chemistry for the development of point-of-care platforms: study of intervening parameters and automation in microfluidics

Grant number: 14/24126-6
Support type:Regular Research Grants
Duration: March 01, 2015 - February 28, 2017
Field of knowledge:Physical Sciences and Mathematics - Chemistry
Principal Investigator:Renato Sousa Lima
Grantee:Renato Sousa Lima
Home Institution: Centro Nacional de Pesquisa em Energia e Materiais (CNPEM). Ministério da Ciência, Tecnologia, Inovações e Comunicações (Brasil). Campinas , SP, Brazil
Assoc. researchers: Angelo Luiz Gobbi ; Diego Stéfani Teodoro Martinez ; Fernando Galembeck ; Lauro Tatsuo Kubota

Abstract

This Project addresses an approach created at Microfabrication Laboratory in 2014. Called microemulsification-based method (MEC), it employs for the first time the thermodynamic stabilization of dispersions (microemulsification) to perform analytical determinations. The generation of nanodroplets in stable dispersions of microemulsions (MEs; transparent) allows complex chemical determinations by monitoring the change of turbidity from emulsions or Winsor systems (cloudy). More specifically, the MEC relies on effect of the analyte content over the dispersion entropy, affecting the microemulsification and, thus, the minimum volume fraction of amphiphile required to form ME that expresses the method analytical response. Unlike the colorimetry wherein the signal depends on color intensity, the measurement of the MEC analytical response is based on a binary chemical information, the cloudy-transparent conversion that occurs with the microemulsification process. This fact ensures accurate determinations simply through visual detection, bypassing any instrumental detection techniques. MEC combines simplicity, rapidity, low consumption of chemicals, and portability with high analytical performance taking into account parameters such as precision, linearity, robustness, and accuracy. Thereby, this approach is a promising alternative for the development of point-of-use technologies. So far, the reliability of the MEC was evaluated by analyzing water in ethanol fuel and monoethylene glycol in complex samples of liquefied natural gasprovided by Petrobras. The assays to analyze water demonstrated that the analytical performance depends on composition of the ME. It sums flexibility to the developed method. The tests to natural gas, in turn, showed the potential of the MEC for the analysis of complex matrices. The natural gas samples exhibited color, particulate material, high ionic strength, and diverse compounds including metals, carboxylic acids, and anions. These samples had a conductivity of up to 2,630 µS cm-1; the conductivity of pure monoethylene glycol was only 0.30 µS cm-1. Despite such downsides, the method allowed accurate measures bypassing steps such as extraction, preconcentration and dilution of the sample. In addition, the levels of robustness were promising. This parameter was assessed by investigating the effect of (i) deviations in volumetric preparation of the dispersions and (ii) changes in temperature and ionic strength over the analyte contents recorded by the method. This project specifically focuses on (i) investigation of the effect of diverse intervening factors (amphiphile and aqueous phase nature, temperature, and ionic strength) over the analytical performance and (ii) deployment of a microfluidic device integrating smartphone for accomplishment of MEC. Such steps will be performed with intent to get a better understanding about the developed method and to deploy a potential analytical tool for routine point-of-care experiments. The advent of the smartphone in the quantitative analytical chemistry is a current and frontier knowledge area. Their intrinsic characteristics such as portability, widespread usage, communication, and computation will contribute notoriously in the next years to develop lab-on-a-chip platforms capable of performing accurate, rapid, and automatic in situ experiments, eliminating the need for qualified operators (POC assays). In special, we believe the employment of the smartphone-coupled microfluidics to conduct the MEC is a promising way concerning the construction of these platforms. Besides their ideal features as rapid testing tool, such approach has high compatibility of automation in microchips incorporating smartphone as discussed in the current project. (AU)

Scientific publications (10)
(References retrieved automatically from Web of Science and SciELO through information on FAPESP grants and their corresponding numbers as mentioned in the publications by the authors)
MARTUCCI, DIEGO H.; TODAO, FAGNER R.; SHIMIZU, FLAVIO M.; FUKUDOME, TIAGO M.; SCHWARZ, STEPHANE DE F.; CARRILHO, EMANUEL; GOBBI, ANGELO L.; OLIVEIRA, JR., OSVALDO N.; LIMA, RENATO S. Auxiliary electrode oxidation for naked-eye electrochemical determinations in microfluidics: Towards on-the-spot applications. Electrochimica Acta, v. 292, p. 125-135, DEC 1 2018. Web of Science Citations: 2.
SHIMIZU, FLAVIO M.; PASQUALETI, ANIELLI M.; TODAO, FAGNER R.; DE OLIVEIRA, JESSICA F. A.; VIEIRA, LUIS C. S.; GONCALVES, SUELY P. C.; DA SILVA, GABRIELA H.; CARDOSO, MATEUS B.; GOBBI, ANGELO L.; MARTINEZ, DIEGO S. T.; OLIVEIRA JR, OSVALDO N.; LIMA, RENATO S. Monitoring the Surface Chemistry of Functionalized Nanomaterials with a Microfluidic Electronic Tongue. ACS SENSORS, v. 3, n. 3, p. 716-726, MAR 2018. Web of Science Citations: 8.
SHIMIZU, FLAVIO M.; TODAO, FAGNER R.; GOBBI, ANGELO L.; OLIVEIRA, JR., OSVALDO N.; GARCIA, CARLOS D.; LIMA, RENATO S. Functionalization-Free Microfluidic Electronic Tongue Based on a Single Response. ACS SENSORS, v. 2, n. 7, p. 1027-1034, JUL 2017. Web of Science Citations: 13.
HIGA, KAREN M.; DE CAMARGO, CAMILA L.; GIORDANO, GABRIELA F.; SILVA, IVO P. O.; GOBBI, ANGELO L.; KUBOTA, LAURO T.; LIMA, RENATO S. Intervening factors in the performance of a naked-eye microemulsification-based method and improvements in analytical frequency. ANALYTICAL METHODS, v. 9, n. 22, p. 3347-3355, JUN 14 2017. Web of Science Citations: 0.
SHIROMA, LETICIA S.; OLIVEIRA, ALINE F.; LOBO-JUNIOR, EULICIO O.; COLTRO, WENDELL K. T.; GOBBI, ANGELO L.; DE LA TORRE, LUCIMARA G.; LIMA, RENATO S. High adhesion strength and hybrid irreversible/reversible full-PDMS microfluidic chips. Analytica Chimica Acta, v. 951, p. 116-123, JAN 25 2017. Web of Science Citations: 6.
GIORDANO, GABRIELA F.; VICENTINI, MARCIA B. R.; MURER, RUI C.; AUGUSTO, FABIO; FERRAO, MARCO F.; HELFER, GILSON A.; DA COSTA, ADILSON B.; GOBBI, ANGELO L.; HANTAO, LEANDRO W.; LIMA, RENATO S. Point-of-use electroanalytical platform based on homemade potentiostat and smartphone for multivariate data processing. Electrochimica Acta, v. 219, p. 170-177, NOV 20 2016. Web of Science Citations: 13.
TEIXEIRA, CARLOS A.; GIORDANO, GABRIELA F.; BELTRAME, MAISA B.; VIEIRA, LUIS C. S.; GOBBI, ANGELO L.; LIMA, RENATO S. Renewable Solid Electrodes in Microfluidics: Recovering the Electrochemical Activity without Treating the Surface. Analytical Chemistry, v. 88, n. 22, p. 11199-11206, NOV 15 2016. Web of Science Citations: 8.
SHIROMA, LETCIA S.; PIAZZETTA, MARIA H. O.; DUARTE-JUNIOR, GERSON F.; COLTRO, WENDELL K. T.; CARRILHO, EMANUEL; GOBBI, ANGELO L.; LIMA, RENATO S. Self-regenerating and hybrid irreversible/reversible PDMS microfluidic devices. SCIENTIFIC REPORTS, v. 6, MAY 16 2016. Web of Science Citations: 17.
DA CUNHA, JAQUELINE G.; SHIROMA, LEANDRO Y.; GIORDANO, GABRIELA F.; COUTO, BRUNO C.; CARVALHO, ROGERIO M.; GOBBI, ANGELO L.; KUBOTA, LAURO T.; LIMA, RENATO S. Microemulsification-Based Method: Analysis of Monoethylene Glycol in Samples Related to Natural Gas Processing. ENERGY & FUELS, v. 29, n. 9, p. 5649-5654, SEP 2015. Web of Science Citations: 2.
GIORDANO, GABRIELA F.; SHIROMA, LEANDRO Y.; GOBBI, ANGELO L.; KUBOTA, LAURO T.; LIMA, RENATO S. Microemulsification-based method: analysis of ethanol in fermentation broth of sugar cane. ANALYTICAL METHODS, v. 7, n. 23, p. 10061-10066, 2015. Web of Science Citations: 2.

Please report errors in scientific publications list by writing to: cdi@fapesp.br.