Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Determination of europium isotope ratios in natural waters by MC-ICP-MS

Full text
Author(s):
Arantes de Carvalho, Gabriel Gustinelli ; Oliveira, Pedro Vitoriano ; Yang, Lu
Total Authors: 3
Document type: Journal article
Source: Journal of Analytical Atomic Spectrometry; v. 32, n. 5, p. 987-995, MAY 1 2017.
Web of Science Citations: 8
Abstract

An analytical protocol for the accurate and precise determination of the europium isotope ratio in low level natural waters is presented for the first time by using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Parameters affecting the separation of Eu from the matrix by employing a single-step column separation with di(2-ethylhexyl) orthophosphoric acid (HDEHP) resin were investigated in detail. Matrix elements (e.g., alkali, alkali-earth and transition metals) were efficiently removed and Eu was quantitatively separated from other rare earth elements (REEs) by sequential elution using gradient HCl concentrations (from 0.25 to 0.75 mol L-1). Fractionation of Eu isotopes in the column was not observed, since quantitative europium recovery (101.2 +/- 0.5% mean and 1 SD, n = 3) was obtained (data based on 150 mL SLRS-6 river water CRM test portions spiked with 1.0 ng mL(-1) Eu standard solution). A combined standard-sample bracketing with internal normalization method was employed for the mass bias correction, wherein Gd was added to both the sample and standard as an internal standard. The developed method was validated by processing 0.02 ng mL(-1) Eu spiked river water CRM SLRS-6 (wherein Eu was removed first by using the above-mentioned column separation method) using the proposed method, and satisfying results (delta Eu-151/153 value of 0.01 +/- 0.02 parts per thousand; 1 SD) relative to Eu standard solution were obtained. No significant differences were found in the delta Eu-151/153 values in river water SLRS-6, drinking water AQUA-1 and collected groundwater samples from Brazil, which ranged from -0.07 +/- 0.02 to 0.12 +/- 0.24 (mean +/- 1 SD, n = 5). (AU)

FAPESP's process: 15/25094-3 - Isotopic investigations in groundwater by inductively coupled plasma mass spectrometry
Grantee:Gabriel Gustinelli Arantes de Carvalho
Support type: Scholarships abroad - Research Internship - Post-doctor
FAPESP's process: 15/06161-1 - Application of polymeric substrates for the separation and concentration of rare earth elements from waters
Grantee:Gabriel Gustinelli Arantes de Carvalho
Support type: Scholarships in Brazil - Post-Doctorate