Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Is one dental mini-implant biomechanically appropriate for the retention of a mandibular overdenture? A comparison with Morse taper and external hexagon platforms

Full text
Author(s):
Borges, Guilherme Almeida [1] ; Camacho Presotto, Anna Gabriella [1] ; Caldas, Ricardo Armini [2] ; Pisani, Marina Xavier [1] ; Mesquita, Marcelo Ferraz [1]
Total Authors: 5
Affiliation:
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, UNICAMP, Piracicaba - Brazil
[2] Fed Univ Santa Catarina UFSC, Dept Dent, Rua Delfino Conti 1240, BR-88040900 Florianopolis, SC - Brazil
Total Affiliations: 2
Document type: Journal article
Source: JOURNAL OF PROSTHETIC DENTISTRY; v. 125, n. 3, p. 491-499, MAR 2021.
Web of Science Citations: 0
Abstract

Statement of problem. Limited information is available to clinicians on the use of dental mini implants (MI) as opposed to standard-diameter implants (SDIs) for the stabilization of implant retained mandibular overdentures (MOs). Purpose. The purpose of this in vitro and finite element analysis study was to analyze and compare the biomechanical behavior of MOs with either 1 or 2 implants with external hexagon (EH), Morse taper (MT) SDIs, and MIs. Material and methods. Thirty photoelastic models (n=30) of each group (n=5) of SDIs (EH-1, EH-2, MT-1, MT-2) and MI (MI-1, MI-2) were fabricated for posterior, peri-implant, and total maximum shear stress evaluation by quantitative photoelastic analysis. One specimen of each group was further used to create the 6 computational models to be analyzed by finite element analysis. The maximum von Mises values and stress maps were plotted for each ductile component. Two types of load were applied to the overdenture: a150-N load bilaterally and simultaneously on the first molar and a 100-N load on the incisal edge of the central incisors at a 30-degree angle. The data were subjected to the 2-way ANOVA test and the Tukey honestly significant difference test (a=.05). Results. The EH-2 and MT-2 showed the lowest posterior (P<.001) and total (P .05) mean shear stress values. For peri-implant shear stress, no difference was found among all groups (P .05). Regardless of the loading area, the MI-1 and MI-2 groups showed the lowest von Mises stress values. However, for implant housing, the MI-1 group, under incisor loading, presented greater stress, followed by MT-1, EH-1, EH-2, MI-2, and MT-2. The attachment was the most overloaded structure, with high values under incisor loading, especially for the groups with 2 implants (MT-2, EH-2) as compared with the other models. Conclusions. Biomechanically, regardless of the implant number, MI is a promising rehabilitation method with similar peri-implant shear stress and lower von Mises stress on the implant when compared with SDIs for MOs. (J Prosthet Dent 2021;125:491-9) (AU)

FAPESP's process: 18/03136-4 - Mandibular overdentures retained by one or two implants: comparison between mini implants and conventional implants with different types of connection - photoelastic and finite element analysis
Grantee:Guilherme Almeida Borges
Support Opportunities: Scholarships in Brazil - Master
FAPESP's process: 14/19098-3 - Influence of the number and type of implant, implant / abutment connection and attachment systems on the stress distribution in mandibular Overdentures - Photoelastic Analysis and Finite Elements in 3D
Grantee:Marina Xavier Pisani
Support Opportunities: Scholarships in Brazil - Post-Doctoral