Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Non-Destructive Current Sensing for Energy Efficiency Monitoring in Buildings with Environmental Certification

Texto completo
Autor(es):
Moreira Mota, Lia Toledo [1] ; Mota, Alexandre de Assis [1] ; Coiado, Lorenzo Campos [1]
Número total de Autores: 3
Afiliação do(s) autor(es):
[1] Pontifical Catholic Univ Campinas, CEATEC, BR-13086900 Sao Paulo - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: SENSORS; v. 15, n. 7, p. 16740-16762, JUL 2015.
Citações Web of Science: 1
Resumo

Nowadays, buildings environmental certifications encourage the implementation of initiatives aiming to increase energy efficiency in buildings. In these certification systems, increased energy efficiency arising from such initiatives must be demonstrated. Thus, a challenge to be faced is how to check the increase in energy efficiency related to each of the employed initiatives without a considerable building retrofit. In this context, this work presents a non-destructive method for electric current sensing to assess implemented initiatives to increase energy efficiency in buildings with environmental certification. This method proposes the use of a sensor that can be installed directly in the low voltage electrical circuit conductors that are powering the initiative under evaluation, without the need for reforms that result in significant costs, repair, and maintenance. The proposed sensor consists of three elements: an air-core transformer current sensor, an amplifying/filtering stage, and a microprocessor. A prototype of the proposed sensor was developed and tests were performed to validate this sensor. Based on laboratory tests, it was possible to characterize the proposed current sensor with respect to the number of turns and cross-sectional area of the primary and secondary coils. Furthermore, using the Least Squares Method, it was possible to determine the efficiency of the air core transformer current sensor (the best efficiency found, considering different test conditions, was 2%), which leads to a linear output response. (AU)

Processo FAPESP: 12/51642-0 - RTI - 2012 - Plano anual de aplicação da parcela institucional da reserva técnica
Beneficiário:Alexandre de Assis Mota
Modalidade de apoio: Auxílio à Pesquisa - Reserva Técnica para Infraestrutura Institucional de Pesquisa