Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

A simple, sensitive and reduced cost paper-based device with low quantity of chemicals for the early diagnosis of Plasmodium falciparum malaria using an enzyme-based colorimetric assay

Texto completo
Autor(es):
dos Santos, Glauco Pilon [1, 2] ; Correa, Catia Crispilho [3] ; Kubota, Lauro Tatsuo [1, 2]
Número total de Autores: 3
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Dept Analyt Chem, Inst Chem, POB 6154, BR-13084971 Campinas, SP - Brazil
[2] Univ Estadual Campinas, Inst Chem, Natl Inst Sci & Technol Bioanalyt, POB 6154, BR-13084971 Campinas, SP - Brazil
[3] CNPEM, Brazilian Nanotechnol Natl Lab LNNano, BR-13083970 Campinas, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: SENSORS AND ACTUATORS B-CHEMICAL; v. 255, n. 2, p. 2113-2120, FEB 2018.
Citações Web of Science: 9
Resumo

In this study, we report the development of a paper-based platform with low amount of reagents for the detection of the histidine-rich protein 2 by an enzyme-based colorimetric assay aiming for the early diagnosis of Plasmodium falciparum malaria. A CO2 laser cutter was used for the fabrication of the device in a simple layout suitable to perform the lateral flow assay, which consisted in a region for sample addition, a detection zone and an absorbent pad, all of which were linked by microfluidic channels. Investigations related to the performance of the sandwich immunoassay in the nitrocellulose membrane shown that the blocking and washing steps are essential to promote efficient antigen-antibody recognition and to generate reliable results, avoiding misinterpretations. Several parameters were also evaluated and the experimental conditions were optimized: concentration and incubation time with the capture antibody (50 mu g mL(-1) and 5 min, respectively); BSA solution at 1.5% (w/v) containing 0.1% (v/v) Tween 20 for blocking the nitrocellulose and 10 min as the incubation time; 10 mmol L-1 Tris-HCl buffer solution at pH 7.4 containing 0.15 mol L-1 NaCl and 0.1% (v/v) Tween 20 for washing the device before adding the ready to use TMB substrate at the detection zone. The system demonstrated a good sensitivity and detectability reaching a visual and calculated limit of detection of 5.0 ng mL(-1) (65 parasites mu L-1) and 4.5 ng mL(-1) (59 parasites mu L-1) respectively, a clinically relevant concentration that should be sufficient to identify the disease in the appearance of the first symptoms and with the advantage of not needing to use nanostructures or other strategy for signal amplification beyond the enzyme. (C) 2017 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 13/09171-2 - Construção e aplicação de dispositivo analítico à base de papel para o diagnóstico da malária causada por Plasmodium falciparum
Beneficiário:Glauco Pilon dos Santos
Linha de fomento: Bolsas no Brasil - Doutorado
Processo FAPESP: 08/57805-2 - Instituto de Bioanalítica
Beneficiário:Lauro Tatsuo Kubota
Linha de fomento: Auxílio à Pesquisa - Temático