Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Graphene particles supported on silica as sorbent for residue analysis of tetracyclines in milk employing microextraction by packed sorbent

Texto completo
Autor(es):
Soares Maciel, Edvaldo Vasconcelos [1] ; Fumes, Bruno Henrique [1] ; de Toffoli, Ana Lucia [1] ; Lancas, Fernando Mauro [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Inst Chem Sao Carlos, Sao Carlos, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: ELECTROPHORESIS; v. 39, n. 15, SI, p. 2047-2055, AUG 2018.
Citações Web of Science: 3
Resumo

This paper describes the use of graphene-based sorbents for determination of four tetracyclines in milk. The synthesized materials were combined with microextraction by packed sorbent (MEPS) to act as the sample preparation step. The extraction performance of these sorbents was compared to commercial phases, and graphene supported on silica provided the best results. The analytical method optimization was carried out by employing experimental design. Firstly, an evaluation of the experimental variables (elution solvent, use of EDTA, ionic force, and pH of the washing solution) was made by a 2(4-1) factorial experimental design. The variables sampling, washing and elution cycles of MEPS were further optimized under a full 2(3) experimental design. The validation parameters were determined under optimized conditions resulting in a linearity ranging from 15 to 110g/L with R-2 values above 0.98, and LOQs ranging from 0.05 to 0.9g/L. The accuracy ranged from 87.9 to 118.4% and intra/inter-day precision reported by the RSDs were lower than 19%. The proposed and validated method was successfully applied to the analysis of 11 milk samples from different animals, revealing traces of tetracyclines in only two of them. This study focused on the evaluation of graphene-based sorbents combined with MEPS for tetracycline analysis provided equivalent or even better results than other proposed methods, suggesting being a sensitive, fast and reliable alternative method for the determination of tetracyclines in milk samples. (AU)

Processo FAPESP: 15/15462-5 - Emprego do grafeno como material sorvente em técnicas miniaturizadas de preparo de amostra
Beneficiário:Bruno Henrique Fumes
Linha de fomento: Bolsas no Brasil - Doutorado
Processo FAPESP: 14/07347-9 - Desenvolvimento de novos materiais e dispositivos para técnicas miniaturizadas de preparo de amostras na área de segurança alimentar
Beneficiário:Fernando Mauro Lanças
Linha de fomento: Auxílio à Pesquisa - Regular