An electrochemical furosemide sensor based on penc... - BV FAPESP
Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

An electrochemical furosemide sensor based on pencil graphite surface modified with polymer film Ni-salen and Ni(OH)(2)/C nanoparticles

Texto completo
Autor(es):
Martins, Thiago S. [1] ; Bott-Neto, Jose L. [1] ; Raymundo-Pereira, Paulo A. [2] ; Ticianelli, Edson A. [1] ; Machado, Sergio A. S. [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Sao Carlos Inst Chem, Ave Trabalhador Sao Carlense 400, BR-13560970 Sao Carlos, SP - Brazil
[2] Univ Sao Paulo, Sao Carlos Inst Phys, Ave Trabalhador Sao Carlense 400, BR-13560970 Sao Carlos, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: SENSORS AND ACTUATORS B-CHEMICAL; v. 276, p. 378-387, DEC 10 2018.
Citações Web of Science: 3
Resumo

In this work, an advanced electrochemical sensor based on pencil graphite electrode modified via electropolymerization of the N,N'-bis(salicylidene) ethylenediaminonickel(II) monomer in the presence of carbon supported Ni(OH)(2) nanoparticles(here called as poly{[}Ni(salen)] and Ni(OH)(2)/C) was developed and investigated for furosemide(FUR) quantification in alkaline medium. The electrochemical sensor and its components were extensively characterized by physico-chemical techniques, while the furosemide oxidation process was investigated by in situ Fourier transform infrared spectroscopy(in situ FTIR). These results indicate that the oxidation of furosemide leads to the formation of 2-amino-4-chloro-5-sulfamoylbenzoate and 5-hydroxy-furan-2-carboxylate in these conditions. The electrochemical response of the modified graphite electrode(MGE) for the determination of FUR was measured by cyclic voltammetry(CV). The calibration curve(change of voltammetric peak current vs. FUR concentration) presented a linear range from 2.5 x 10(-10) M to 2.7 x 10(-9) M with a calculated limit of detection as low as 1.4 x 10(-10) M under the optimized conditions, which is lower than values reported in the literature. The ultra-low sensitivity obtained with the MGE sensor was attributed to an additiveeffect involving the poly{[}Ni(salen)] film and the high surface carbon-supported Ni(OH)(2) nanoparticles. (AU)

Processo FAPESP: 16/01919-6 - Design e fabricação de dispositivos flexíveis nanoestruturados para detecção de biomarcadores
Beneficiário:Paulo Augusto Raymundo Pereira
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 16/12759-0 - Desenvolvimento de uma metodologia eletroanalítica avançada para a quantificação dos hormônios 17b-estradiol e 17alfaetinilestradiol em amostras de águas de abastecimento, empregando eletrodos modificados com grafeno, nanopartículas de ouro e quantum dots
Beneficiário:Sergio Antonio Spinola Machado
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 13/16930-7 - Eletrocatálise V: processos eletrocatalíticos de interconversão entre as energias química e elétrica
Beneficiário:Edson Antonio Ticianelli
Modalidade de apoio: Auxílio à Pesquisa - Temático