Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Automated online coupling of robot-assisted single drop microextraction and liquid chromatography

Texto completo
Autor(es):
Vargas Medina, Deyber Arley [1] ; Rodriguez Cabal, Luis Felipe [1] ; Titato, Guilherme Miola [1] ; Lancas, Fernando Mauro [1] ; Santos-Neto, Alvaro Jose [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Sao Carlos Inst Chem, BR-13566590 Sao Carlos, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Journal of Chromatography A; v. 1595, p. 66-72, JUN 21 2019.
Citações Web of Science: 0
Resumo

A high-throughput and innovative setup has been developed to automate the online integration of single drop microextraction (SDME), liquid chromatography (LC) and high-resolution mass spectrometry (QqToF). SDME and LC were online hyphenated for the first time. SDME was carried out by a lab-made cartesian robot actuating a 100 mu L syringe, equipped with a three-way solenoid microvalve that allowed the online transference of the enriched extract to the chromatographic system, through a six-port switching valve. The complete method, including the synchronized robot action, valves, and the analytical instruments, was controlled by an Arduino Mega board. The merits of the proposed setup were demonstrated by the triazines determination in coconut water samples. The most relevant extraction parameters, such as drop size, exposure time, stirring effect, salt addition and pH were systematically investigated. Under optimized conditions (60 mu L drop volume and 10 min extraction time), the LC-UV enrichment factors (EF) and the extraction recoveries (ER) ranged between 15.2-18.4 and 11.4-13.8%, respectively. Using the SDME-LC-MS setup, the linear range, detection limit (S/N = 3) and precision (RSD, n = 6 at 0.25 mu g L-1 level of concentration) were 0.25-25 mu g L-1, 0.10 mu g L-1 and 16.8% for simazine; 0.25-25 mu g L-1, 0.05 mu g L-1 and 14.7% for atrazine; and 0.25-25 mu g L-1, 0.05 mu g L-1 and 18.5% for propazine, respectively. Although none of the analytes were detected in the evaluated commercial samples, the results indicate that the proposed online SDME-LC setup is a competitive analytical strategy for the determination of target organic compounds in complex matrices. (C) 2019 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 17/02147-0 - Cromatografia líquida em uma gota e seu acoplamento com espectrometria de massas: estratégias instrumentais, desenvolvimento de materiais, automatização e aplicações analíticas
Beneficiário:Fernando Mauro Lanças
Linha de fomento: Auxílio à Pesquisa - Temático
Processo FAPESP: 16/21950-5 - Estratégias automatizadas para preparo de amostras miniaturizado: SDME com agitação na seringa e integração online com a cromatografia líquida
Beneficiário:Deyber Arley Vargas Medina
Linha de fomento: Bolsas no Exterior - Estágio de Pesquisa - Doutorado
Processo FAPESP: 10/19910-9 - Desenvolvimento de estratégias de química verde em cromatografia e aplicação na avaliação da degradação de antibióticos em águas residuárias por biorreatores anaeróbios de leito fixo
Beneficiário:Alvaro José dos Santos Neto
Linha de fomento: Auxílio à Pesquisa - Regular