Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Hollow-fibre liquid-phase microextraction and gas chromatography-mass spectrometric determination of amphetamines in whole blood

Texto completo
Autor(es):
Bombana, Henrique Silva [1] ; dos Santos, Marcelo Filonzi [1] ; Munoz, Daniel Romero [1] ; Leyton, Vilma [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Fac Med, Av Dr Arnaldo, 455 Cerqueira Cesar, BR-01246903 Sao Paulo - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES; v. 1139, FEB 15 2020.
Citações Web of Science: 0
Resumo

Here, we present a fully validated method using a hollow-fibre liquid-phase microextraction technique for the determination by gas chromatography-mass spectrometry (GC-MS) of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxyethylamphetamine (MDEA) in whole blood. The validation parameters presented successful values within those recommended by the Scientific Working Group for Forensic Toxicology (SWGTox) in the Standard Practices for Method Validation in Forensic Toxicology. The limits of detection ranged from 1 to 3 ng/mL, and the limits of quantification ranged from 2 to 5 ng/mL. The determination coefficients (r(2)) ranged from 0.990 to 0.997, and the method presented good intraday and interday accuracy (from 90.4% to 97.2%) and satisfactory recovery (from 68% to 110%). No carryover was observed. The heteroscedasticity was tested, and only AMP presented homoscedasticity. Weighting factors were applied to correct the linearity of MET (1/x(2)), MDA (1/x), FEN (1/x(1/2)), MDMA (1/x(2)) and MDEA (1/y). Dilution integrity was tested at ratios of 1:2, 1:5 and 1:10, and all maintained intraday precision (from 94.9% to 99.3%) and interday precision (from 89.4% to 94.9%). The validated method was applied to six real whole blood samples from individuals suspected of consuming ecstasy, and MDMA, MDA and amphetamine were successfully identified and quantified. (AU)

Processo FAPESP: 16/20214-3 - Verificação do uso de drogas e medicamentos por motoristas profissionais através da análise toxicológica de fluido oral: desenvolvimento de novos métodos analíticos e estudos de prevalência
Beneficiário:Vilma Leyton
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 17/13882-2 - Drogas ilícitas em sangue: novas metodologias de análises toxicológicas
Beneficiário:Henrique Silva Bombana
Modalidade de apoio: Bolsas no Brasil - Doutorado