Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Restricted access carbon nanotube for microextraction by packed sorbent to determine antipsychotics in plasma samples by high-performance liquid chromatography-tandem mass spectrometry

Texto completo
Autor(es):
Cruz, Jonas Carneiro [1] ; de Faria, Henrique Dipe [2] ; Figueiredo, Eduardo Costa [2] ; Queiroz, Maria Eugenia Costa [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Preto, Dept Quim, BR-14040901 Ribeirao Preto, SP - Brazil
[2] Fed Univ Alfenas Unifal MG, Lab Toxicant & Drug Anal LATF, Gabriel Monteiro Silva St 700, BR-37130000 Alfenas, MG - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: ANALYTICAL AND BIOANALYTICAL CHEMISTRY; v. 412, n. 11, SI FEB 2020.
Citações Web of Science: 0
Resumo

This manuscript describes the development of the restricted access carbon nanotube (RACNT) as a selective stationary phase for microextraction by packed sorbent (MEPS) to determine antipsychotics (chlorpromazine, clozapine, olanzapine, and quetiapine) in untreated plasma samples from schizophrenic patients by ultra-high liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The synthesis was achieved by chemically covering commercial multi-walled carbon nanotubes with bovine serum albumin (BSA) to subsequently pack the material in a polyethylene conical tube (1000 mu L). The RACNTs' sorbents were able to exclude about 97% of the plasma proteins, maintaining the same performance for about 100 assays. The MEPS variables (sample pH, draw-eject cycles, desorption and phase cleanup) were evaluated to improve sensibility and selectivity. The MEPS/UHPLC-MS/MS method was linear at concentrations ranging from the lower limit of quantification (10.0 ng mL(-1)) to the upper limit of quantification (200-700 ng mL(-1)) with coefficients of determinations higher than 0.99. The precision assays presented relative standard deviation (RSD) values lower than 13%, and the accuracy assays presented relative error (RE) values that ranged from - 8.01 to 11.53%. Neither significant matrix effects nor carryover was observed. The developed method was successfully applied to determine antipsychotics drugs for therapeutic drug monitoring of schizophrenic patients. (AU)

Processo FAPESP: 17/02147-0 - Cromatografia líquida em uma gota e seu acoplamento com espectrometria de massas: estratégias instrumentais, desenvolvimento de materiais, automatização e aplicações analíticas
Beneficiário:Fernando Mauro Lanças
Linha de fomento: Auxílio à Pesquisa - Temático