Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Influence of Different Implants on the Biomechanical Behavior of a Tooth-Implant Fixed Partial Dentures: A Three-Dimensional Finite Element Analysis

Texto completo
Autor(es):
Lencioni, Karina Albino [1] ; Noritomi, Pedro Yoshito [2] ; Macedo, Ana Paula [1] ; Ribeiro, Ricardo Faria [1] ; de Almeida, Rossana Pereira [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Dent Sch Ribeirao Preto, Dept Dent Mat & Prosthodont, Ribeirao Preto, SP - Brazil
[2] Renato Archer Informat Technol Ctr CTI, Campinas, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF ORAL IMPLANTOLOGY; v. 46, n. 1, p. 27-34, FEB 2020.
Citações Web of Science: 1
Resumo

This study analyzed the biomechanical behavior of rigid and nonrigid tooth-implant supported fixed partial dentures. Different implants were used to observe the load distribution over teeth, implants, and adjacent bone using three-dimensional finite element analysis. A simulation of tooth loss of the first and second right molars was created with an implant placed in the second right molar and a prepared tooth with simulated periodontal ligament (PDL) in the second right premolar. Configurations of two types of implants and their respective abutments-external hexagon (EX) and Morse taper (MT)-were transformed into a 3D format. Metal-ceramic fixed partial dentures were constructed with rigid and nonrigid connections. Mesh generation and data processing were performed on the 3D finite element analysis (FEA) results. Static loading of 50 N (premolar) and 100 N (implant) were applied. When an EX implant was used, with a rigid or nonrigid connection, there was intrusion of the tooth in the distal direction with flexion of the periodontal ligament. Tooth intrusion did not occur when the MT implant was used independent of a rigid or nonrigid connection. The rigid or nonrigid connection resulted in a higher incidence of compressive forces at the cortical bone as well as stress in the abutment/pontic area, regardless of whether EX or MT implants were used. MT implants have a superior biomechanical performance in tooth-implant supported fixed partial dentures. This prevents intrusion of the tooth independent of the connection. Both types of implants studied caused a greater tendency of compressive forces at the crestal area. (AU)

Processo FAPESP: 11/11190-0 - Próteses parciais fixas apoiadas sobre conexão dente-implante: análise do comportamento biomecânico por meio de fotoelasticidade e elementos finitos
Beneficiário:Rossana Pereira de Almeida
Modalidade de apoio: Auxílio à Pesquisa - Regular