Application of one-point calibration LIBS for quan... - BV FAPESP
Busca avançada
Ano de início
Entree


Application of one-point calibration LIBS for quantification of analytes in samples with distinct matrix characteristics: a case study with Hg

Texto completo
Autor(es):
Leva Borduchi, Luis Carlos ; Menegatti, Carlos Renato ; Milori, Debora Marcondes Bastos Pereira ; Izario Filho, Helcio Jose ; Villas-Boas, Paulino Ribeiro
Número total de Autores: 5
Tipo de documento: Artigo Científico
Fonte: Journal of Analytical Atomic Spectrometry; v. 38, n. 5, p. 9-pg., 2023-03-17.
Resumo

Laser-induced breakdown spectroscopy (LIBS) is a powerful analytical technique for elemental analysis, but matrix effects can significantly affect its accuracy. In this work, we propose the use of calibration-free LIBS (CF-LIBS) with the one-point calibration (OPC) method to reduce matrix effects in the quantification of mercury (Hg) for seven soil and eleven landfill leachate samples, with Hg concentration ranging from 50 to 1000 mg kg(-1). To improve sensitivity, we employed a double-pulse LIBS system with parameters optimized for each of the two sample matrices. A single soil sample was used to calibrate the OPC factors, which were then applied to the CF-LIBS calculations for the other samples. Using CF-LIBS corrected with the OPC method, we achieved an average error of 4.3% in the quantification of Hg for the two sample sets. This result indicates that these methods have the potential not only to reduce matrix effects but also to compensate for variations in LIBS system optimization for either matrix (soils and leachates) in the quantification of Hg. Therefore, the combination of these methods opens new possibilities for LIBS analyses, where the system can be optimized for each element and sample matrix, and the quantification can be performed with CF-LIBS, as long as the requirements for local thermodynamic equilibrium are fulfilled. Further studies with other elements, matrices, and measurement conditions are needed to validate and expand these findings. (AU)

Processo FAPESP: 17/19248-3 - Utilização da técnica LIBS para estudo de metais pesados em amostras de percolado líquido
Beneficiário:Carlos Renato Menegatti
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 22/05451-0 - Redução do efeito de matriz em análises quantitativas de amostras de solos realizadas com a técnica LIBS
Beneficiário:Luis Carlos Leva Borduchi
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica
Processo FAPESP: 13/07276-1 - CEPOF - Centro de Pesquisa em Óptica e Fotônica
Beneficiário:Vanderlei Salvador Bagnato
Modalidade de apoio: Auxílio à Pesquisa - Centros de Pesquisa, Inovação e Difusão - CEPIDs