Photoelastic Analysis of Cemented or Screwed Impla... - BV FAPESP
Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Photoelastic Analysis of Cemented or Screwed Implant-Supported Prostheses With Different Prostheses Connections

Texto completo
Autor(es):
Tonella, Bianca Piccolotto [1] ; Pellizzer, Eduardo Piza [1] ; Ferraco, Renato [1] ; Falcon-Antenucci, Rosse Mary [1] ; Perri de Carvalho, Paulo S. [2] ; Goiato, Marcelo Coelho [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Sao Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, Sao Paulo - Brazil
[2] Sao Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Surg, Sao Paulo - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF ORAL IMPLANTOLOGY; v. 37, n. 4, p. 401-410, AUG 2011.
Citações Web of Science: 11
Resumo

The aim of this study was to evaluate the stress distribution of different retention systems (screwed or cemented) associated with different prosthetic connections (external hexagon, internal hexagon, and Morse taper) in 3-unit implant-supported fixed partial dentures through photoelasticity. Six models were fabricated with photoelastic resin PL-2, and each model contained two implants of 4.0 x 10.0 mm. The models presented different retention systems (screwed and cemented) and different connections (external hexagon, internal hexagon, and Morse taper). The prostheses were standardized and fabricated in Ni-Cr alloy. A circular polariscope was used and axial and oblique (45) loads of 100 N were applied in a universal testing machine. The results were photographed and analyzed qualitatively with a graphic software (Adobe Photoshop). The screwed retention system exhibited higher number of fringes for both axial and oblique loadings. The internal hexagon implant presented better and lower stress distribution for both cemented and screwed prostheses. The oblique loading increased the number of fringes in all models tested. The cemented retention system presented better stress distribution. The internal hexagon implant was more favorable according to the biomechanical standpoint. The oblique load increased stress in all systems and connections tested. (AU)

Processo FAPESP: 07/55061-3 - Análise das tensões em próteses parafusadas e cimentadas com implantes osseointegrados do tipo hexágono externo, interno e cone morse: estudo pelo método da fotoelasticidade
Beneficiário:Eduardo Piza Pellizzer
Modalidade de apoio: Auxílio à Pesquisa - Regular