Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Microshear Bond Strength of Self-etching Systems Associated with a Hydrophobic Resin Layer

Texto completo
Autor(es):
De Vito Moraes, Andre Guaraci ; Francci, Carlos [1] ; Carvalho, Ceci Nunes [2] ; Soares, Silvio Peixoto ; Braga, Roberto Ruggiero
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Fac Dent, Dept Dent Mat, BR-05508000 Sao Paulo - Brazil
[2] Univ Sao Paulo, Dept Dent, BR-05508000 Sao Paulo - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Journal of Adhesive Dentistry; v. 13, n. 4, p. 341-348, AUG 2011.
Citações Web of Science: 4
Resumo

Purpose: To evaluate in vitro the microshear bond strength of adhesive systems applied to dentin according to manufacturers' instructions, associated or not with a hydrophobic layer of unfilled resin. Materials and Methods: Six self-etching adhesives (Clearfil SE Bond, Kuraray Medical; AdheSE, lvoclar Vivadent; Xeno III, Dentsply; I Bond, Heraeus-Kulzer; Bond Force, Tokuyama; Futurabond DC, Voco) were tested. The labial dentin of sixty bovine incisors was exposed, and the teeth were divided into two groups according to the application or not of an extra hydrophobic resin layer (Scotchbond Multi Purpose Plus, bottle 3). Six composite cylinders (Filtek Z250, 3M ESPE) were built up on each treated surface. Specimens were stored in distilled water at 37 C for 24 h and then subjected to the microshear bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. Microshear bond strength values were analyzed by 2-way ANOVA and Tukey's post-hoc test. Failure mode was determined using a stereomicroscope under 20X magnification. Results: The application of the hydrophobic resin layer did not affect bond strength, except for AdheSE. However, the bond strengths with the hydrophobic layer were similar among the six tested systems (Clearfil: 17.1 +/- 7.9; AdheSE: 14.5 +/- 7.1; Xeno III: 12.8 +/- 7.7; I Bond: 9.5 +/- 5.8; Bond Force: 17.5 +/- 4.1; Futurabond: 7.7 +/- 2.3). When used as recommended by the manufacturers, Bond Force presented statistically higher bond strength than AdheSE and I Bond (p < 0.05) (Clearfil 10.4 +/- 4.9; AdheSE 1.6 +/- 1.6; Xeno III: 9.0 +/- 3.8; I Bond: 3.0 +/- 1.5; Bond Force: 14 +/- 3.9; Futurabond: 8.8 +/- 3.8). Failure mode was predominantly adhesive. Conclusion: The bond strength of the self-etching systems tested was not significantly affected by the application of a hydrophobic layer, but a significant improvement was observed in AdheSE. (AU)

Processo FAPESP: 05/02719-6 - Avaliação da resistência ao micro-cisalhamento de sistemas adesivos autocondicionantes recobertos ou não com um adesivo hidrófobo
Beneficiário:André Guaraci de Vito de Moraes
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica