Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Bleaching technique effect on dentin permeability

Texto completo
Autor(es):
Cannabrava, Vanessa Pavoni ; Fernandes, Samuel Lucas [1] ; Calabria, Marcela Pagani [2] ; Magalhaes, Ana Carolina [3] ; Ishikiriama, Sergio Kiyoshi [1] ; Atta, Maria Teresa [1] ; Wang, Linda [1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Operat Dent Endodont & Dent Mat, Sao Paulo - Brazil
[2] Univ Sagrado Coracao, Dept Operat Dent, Sao Paulo - Brazil
[3] Univ Sao Paulo, Bauru Sch Dent, Dept Biol Sci, Sao Paulo - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: AMERICAN JOURNAL OF DENTISTRY; v. 27, n. 3, p. 145-148, JUN 2014.
Citações Web of Science: 3
Resumo

Purpose: To evaluate the effect of bleaching techniques on dentin permeability. The hypothesis was that the bleaching agent associated or not to etching and/or energy source would be able to increase dentin permeability (conductance). Methods: Fifty 1 mm-thick disks of mid-coronal dentin were obtained from human third molars, which were mounted in a filtration chamber, allowing exposure of a standardized area of 0.282 mm(2). All specimens were treated with 35% liquid phosphoric acid for 15 seconds to maximize dentin permeability. Then they were randomly allocated to five different conditions: C: placebo gel (negative control); HP: Whiteness HP Maxx (WM)-35% hydrogen peroxide; PA-HP: WM preceded by phosphoric acid etching for 15 seconds. HP-E: WM associated to a light source and PA-HP-E: WM preceded by phosphoric acid etching for 15 seconds and associated to a light source. The bleaching agent was applied for 10 minutes with intermediate agitation at 5 minutes. In the groups associated with a light source, it was activated for 30 seconds every 5 minutes. Afterwards, the permeability (Lp) was measured using the Flodec device. The data were collected and analyzed with one-way ANOVA and Tukey's test (P < 0.05). Results: Mean and standard deviation of Lp were: C = 1.92 (1.04); HP = 1.14 (0.29); PA-HP = 14.40 (8.62); HP-E = 4.18 (5.14); PA-HP-E = 27.32 (13.24). Data revealed that phosphoric acid etching could increase the dentin permeability, while the bleaching agent or light curing alone did not. (AU)

Processo FAPESP: 10/05798-2 - Citotoxicidade de resinas compostas a base de dimetacrilato e siloranos em cultura de fibroblasto de polpa dental humana
Beneficiário:Vanessa Pavoni Cannabrava
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica