Electrochromic device with Prussian blue and HPC-based electrolyte

Texto completo
Autor(es):
Assis, L. M. N. [1] ; Sabadini, R. C. [1] ; Santos, L. P. [1] ; Kanicki, J. [2] ; Lapkowski, M. [3] ; Pawlicka, A. [1, 2]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, IQSC, BR-13566590 Sao Carlos, SP - Brazil
[2] Univ Michigan, EECS, Ann Arbor, MI 48109 - USA
[3] Silesian Tech Univ, Dept Phys Chem & Technol Polymers, Fac Chem, PL-44100 Gliwice - Poland
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Electrochimica Acta; v. 182, p. 878-883, NOV 10 2015.
Citações Web of Science: 8
Resumo

Given the importance of the development of electrochromic devices (ECDs) for technological applications small devices with Prussian blue (PB)/hydroxypropyl cellulose (HPC) electrolyte/CeO2-TiO2 configuration were assembled and characterized. The films of PB were obtained galvanostaticaly by applying -0.45 mu A for 300 s. The cyclic voltammetry, in 1 mol L-1 KCl solution, of these films showed a redox pair peaks at well-defined potential of 0.16 V for oxidation and 0.4 V for reduction processes. The ECDs were assembled by combining the HPC-based membrane between the counter-electrode consisting of CeO2-TiO2 and the PB electrochromic layer. The devices were characterized by chronocoulometry coupled with UV-vis transmittance spectroscopy, open circuit properties, and voltammetry. The combination of PB with the transparent HPC electrolyte membrane resulted in an electrochromic device that switched between transparent and blue states by applying -2.6 and 2.0 V, respectively. The charge density measurements showed an increase from -6.0 to -8.4 mC cm(-2) when the potentials where applied for 15 and 60 s, respectively. The UV-vis spectra of the ECDs revealed that switching the ECD between -2.6 and 2.0 V for 15 s/15 s and 60 s/60 s resulted in 28 and 32% of transmittance difference between both states, respectively. The memory test, i.e., the changes of transmittance in open circuit after applying a potential of -2.6 V for 15 s revealed a decrease of transmittance from 60 to 59% in 3 h. The cyclic voltammetry measurements performed from 20 to 500 mV s(-1) showed better resolutions of the oxidation and reduction peaks for higher scan rates. Moreover, it was observed that after 2000 cycles, the charge density decreased from -6.0 to -1.5 mC cm(-2) and the difference of transmittance between colored and bleached state decreased from 28 to 5%. (C) 2015 Elsevier Ltd. All rights reserved. (AU)

Processo FAPESP: 14/21329-3 - Bio-polímeros e filmes finos para aplicação em eletrônica molecular e fotônica
Beneficiário:Carla Cristina Schmitt Cavalheiro
Modalidade de apoio: Auxílio à Pesquisa - Pesquisador Visitante - Internacional
Processo FAPESP: 13/19297-3 - Propriedades refletivas dos dispositivos eletrocrômicos com eletrólitos poliméricos
Beneficiário:Agnieszka Joanna Pawlicka Maule
Modalidade de apoio: Auxílio à Pesquisa - Regular