Assessment of Estimated Phycocyanin and Chlorophyll-a Concentration from PRISMA and OLCI in Brazilian Inland Waters: A Comparison between Semi-Analytical and Machine Learning Algorithms

Texto completo
Autor(es):
de Lima, Thainara Munhoz Alexandre ; Giardino, Claudia ; Bresciani, Mariano ; Barbosa, Claudio Clemente Faria ; Fabbretto, Alice ; Pellegrino, Andrea ; Begliomini, Felipe Nincao
Número total de Autores: 7
Tipo de documento: Artigo Científico
Fonte: REMOTE SENSING; v. 15, n. 5, p. 21-pg., 2023-03-01.
Resumo

The aim of this work is to test the state-of-the-art of water constituent retrieval algorithms for phycocyanin (PC) and chlorophyll-a (chl-a) concentrations in Brazilian reservoirs from hyperspectral PRISMA images and concurrent in situ data. One near-coincident Sentinel-3 OLCI dataset has also been considered for PC mapping as its high revisit time is a relevant element for mapping cyanobacterial blooms. The testing was first performed on remote sensing reflectance (R-rs), as derived by applying two atmospheric correction methods (6SV, ACOLITE) to Level 1 data and as provided in the corresponding Level 2 products (PRISMA L2C and OLCI L2-WFR). Since PRISMA images were affected by sun glint, the testing of three de-glint models was also performed. The applicability of Semi-Analytical (SA) and Mixture Density Network (MDN) algorithms in enabling PC and chl-a concentration retrieval was then tested over three PRISMA scenes; in the case of PC concentration estimation, a Random Forest (RF) algorithm was further applied. Regarding OLCI, the SA algorithm was tested for PC estimation; notably, only SA was calibrated with site-specific data from the reservoir. The algorithms were applied to the R-rs spectra provided by PRISMA L2C products-and those derived with ACOLITE, in the case of OLCI-as these data showed better agreement with in situ measurements. The SA model provided low median absolute error (MdAE) for PRISMA-derived (MdAE = 3.06 mg.m(-3)) and OLCI-derived (MdAE = 3.93 mg.m(-3)) PC concentrations, while it overestimated PRISMA-derived chl-a (MdAE = 42.11 mg.m(-3)). The RF model for PC applied to PRISMA performed slightly worse than SA (MdAE = 5.21 mg.m(-3)). The MDN showed a rather different performance, with higher errors for PC (MdAE = 40.94 mg.m(-3)) and lower error for chl-a (MdAE = 23.21 mg.m(-3)). The results overall suggest that the model calibrated with site-specific measurements performed better and indicates that SA could be applied to PRISMA and OLCI for remote sensing of PC in Brazilian reservoirs. (AU)

Processo FAPESP: 22/01107-2 - Análise da qualidade da água a partir de observações hiperespectrais
Beneficiário:Thainara Munhoz Alexandre de Lima
Modalidade de apoio: Bolsas no Exterior - Estágio de Pesquisa - Mestrado
Processo FAPESP: 20/14613-8 - Desenvolvimento de sistema modular para monitoramento continuo da qualidade de águas interiores por satélite - MAPAQUALI
Beneficiário:Cláudio Clemente Faria Barbosa
Modalidade de apoio: Auxílio à Pesquisa - Regular