Busca avançada
Ano de início
Entree


Does silica-nylon mesh improves the biomechanical response of custom-made mouthguards?

Texto completo
Autor(es):
Mendes Tribst, Joao Paulo ; de Oliveira Dal Piva, Amanda Maria ; Komori de Carvalho, Paula Carolina ; Pereira de Queiroz Goncalves, Pedro Henrique ; Souto Borges, Alexandre Luiz ; de Arruda Paes-Junior, Tarcisio Jose
Número total de Autores: 6
Tipo de documento: Artigo Científico
Fonte: SPORT SCIENCES FOR HEALTH; v. 16, n. 1, p. 10-pg., 2020-03-01.
Resumo

PurposeMouthguards are used for injury prevention due to the high risk of dental and craniofacial injuries during sports activities. Therefore, the aim of this study was to evaluate the effect of silica-nylon mesh on the biomechanical performance of custom-made mouthguards using the finite element method. MethodsTwo custom-made mouthguards were modeled according to the presence or not of silica-nylon mesh. A 500 N load was applied in the region of the upper central incisors for both models. A mesh convergence test of 10% was conducted in the computer-aided analysis software to reduce the error during the results processing. An ideal contact interface was used between all contacts, simulating a situation in which the athlete would not lose his mouthguard upon impact. Also, the contact between the reinforcement and the mouthguard was defined as frictionless after a microscopic investigation. Maximum principal stress parameter was analyzed for bone, mouthguard, teeth, and skull displacement. Stress peaks for mouthguards and teeth were analyzed using one-way ANOVA. ResultsThe results showed that the mesh presence neither influenced the skull displacement or the stress distribution in the bone, teeth or mouthguard. ANOVA showed no difference between the mesh presence or not, with 8.75 +/- 2.00 MPa mean value for the mouthguard and 9.88 +/- 2.75 MPa for the teeth. Conclusions The presence of a silica-nylon mesh did not modify the biomechanical response in the bone, teeth or mouthguard. In addition, even with the mouthguards in position, some damage can occur after the trauma. (AU)

Processo FAPESP: 18/24185-3 - Incorporação de um sistema reforço de nylon e sílica em bases de próteses totais convencionais e reembasadas: estudo do comportamento dimensional frente a ciclagem em micro-ondas
Beneficiário:Tais Maria Cardoso de Oliveira
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica
Processo FAPESP: 17/26591-6 - Avaliação da carga máxima de fratura em próteses parciais fixas temporárias reforçadas com uma malha de nylon
Beneficiário:Jessica Shiotani de Carvalho
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica