Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Effect of Nd:YAG (1064-nm) and Diode Laser (980-nm) EDTA Agitation on Root Dentin Ultrastructure Properties

Texto completo
Autor(es):
de Macedo, Helena Suleiman [1] ; Colucci, Vivian [1] ; Furtado Messias, Danielle Cristine [1] ; Abi Rached-Junior, Fuad Jacob [1] ; Fernandes, Fernanda Silva [1] ; Correa Silva-Sousa, Yara Teresinha [1] ; Raucci-Neto, Walter [1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Ribeirao Preto, UNAERP, Dept Dent, BR-14096000 Ribeirao Preto, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Photomedicine and Laser Surgery; v. 33, n. 7, p. 349-356, JUL 1 2015.
Citações Web of Science: 3
Resumo

Objective: The purpose of this study was to analyze the effects of agitation of 17% ethylenediaminetetraacetic acid (EDTA) with 1064nm Nd:YAG and 980nm diode laser on root dentin microhardness and superficial roughness (with confocal laser scanning microscopy {[}CLSM]). Background data: Root canal irrigants are used in an attempt to minimize the negative effects of smear layer. Materials and methods: Twenty-five bovine roots were sectioned longitudinally and divided into five groups (n=10 each): (1) deionized water, (2) 17% EDTA, (3) 17% EDTA with 60sec manual agitation, (4) 17% EDTA with 50sec diode laser (2 W) agitation, and (5) 17% EDTA with 50sec Nd:YAG (1.5 W) laser agitation. Microhardness and superficial roughness values were calculated before and after the procedures at the cervical, middle, and apical root thirds. Microhardness was statistically analyzed using two way ANOVA, paired t test, and Tukey's tests (=0.05). Roughness was statistically analyzed using Kruskal-Wallis, paired t test, and Student-Newman-Keuls tests (=0.05%). Results: Statistically significant differences in microhardness and roughness were observed between the deionized water group and others. EDTA with 1064nm Nd:YAG or 980nm diode laser presented the lowest microhardness and the highest roughness values and was significantly different from EDTA with manual agitation and EDTA only (p<0.05). However, there were no differences in microhardness or dentin roughness between the root thirds (p>0.05). CLSM analysis showed that the control samples exhibited smoother surfaces than that of the EDTA groups. Conclusions: Nd:YAG 1064nm and 980-nm diode laser EDTA agitation caused greater reduction in microhardness and increased roughness of root dentin than EDTA only or EDTA with manual agitation. (AU)

Processo FAPESP: 13/23535-7 - Avaliação dos efeitos dos lasers Nd:YAG 1.064 nm e diodo 980 nm em associação à protocolos irrigantes na microdureza e rugosidade da dentina radicular
Beneficiário:Helena Suleiman de Macedo
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica