Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Robotic-assisted dynamic large drop microextraction

Texto completo
Autor(es):
Rodriguez Cabal, Luis Felipe [1] ; Vargas Medina, Deyber Arley [1] ; Lima, Adriel Martins [1] ; Lancas, Fernando Mauro [1] ; Santos-Neto, Alvaro Jose [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Inst Chem Sao Carlos, Sao Carlos, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Journal of Chromatography A; v. 1608, DEC 20 2019.
Citações Web of Science: 0
Resumo

By proper design of an innovative extraction device, a lab-made multipurpose autosampler was exploited in the automated performance of the dynamic large drops based microextraction. The pluses of this new analytical strategy were demonstrated in the determination of sulfonamides and fluoroquinolones in surface water samples, by direct immersion single drop microextraction (SDME) and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis. Operational autosampler features and critical experimental factors influencing SDME, including the extraction mode (static or dynamic), extraction, stirring rate, salt addition, drop size, number of cycles and drop exposition time, were comprehensively investigated using both univariate and multivariate optimization. The lab-made autosampler allowed to performance challenging dynamic and static large drop based SDMEs in an automated and effortless way and with minimal requirements of hardware and software. Large stable drops provided high surface area, enhancing the phase ratio and in consequence increasing the analytes uptake. The best extraction efficiencies were obtained as a result of the synergic interaction between the use of large drops and the automated dynamic mode of extraction. The developed method proved to be a reliable, sensitive, and robust analytical tool, with intraday RSDs ranging between 4.0 and 7.6% (n= 6), and interday RSDs between 4.8 and 9.3% (n = 6), and, LOD and LOQ in the range of 15-50 and 35-100 ng L-1, respectively. (C) 2019 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 17/02147-0 - Cromatografia líquida em uma gota e seu acoplamento com espectrometria de massas: estratégias instrumentais, desenvolvimento de materiais, automatização e aplicações analíticas
Beneficiário:Fernando Mauro Lanças
Modalidade de apoio: Auxílio à Pesquisa - Temático
Processo FAPESP: 16/21950-5 - Estratégias automatizadas para preparo de amostras miniaturizado: SDME com agitação na seringa e integração online com a cromatografia líquida
Beneficiário:Deyber Arley Vargas Medina
Modalidade de apoio: Bolsas no Exterior - Estágio de Pesquisa - Doutorado
Processo FAPESP: 10/19910-9 - Desenvolvimento de estratégias de química verde em cromatografia e aplicação na avaliação da degradação de antibióticos em águas residuárias por biorreatores anaeróbios de leito fixo
Beneficiário:Alvaro José dos Santos Neto
Modalidade de apoio: Auxílio à Pesquisa - Regular