Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems

Texto completo
Autor(es):
Ferrairo, Brunna Mota [1] ; Piras, Fernanda Furtado [2] ; Lima, Feranda Ferruzzi [3, 4] ; Honorio, Heitor Marques [5] ; Hungaro Duarte, Marco Antonio [6] ; Sanches Borges, Ana Flavia [6] ; Rubo, Jose Henrique [1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Prosthodont & Periodont, Alameda Doutor Octavio Pinheiro Brisolla 9-75, BR-17012901 Bauru, SP - Brazil
[2] Univ Marilia UNIMAR, Fac Dent, Dept Prosthodont & Periodontol, Ave Higino Muzi Filho 1001, BR-17525902 Marilia, SP - Brazil
[3] Univ Estadual Maringa, Dept Dent, Maringa, Parana - Brazil
[4] Inga Univ Ctr UNINGA, Sch Dent, Dept Restorat Dent & Prosthodont, Maringa, Parana - Brazil
[5] Univ Sao Paulo, Bauru Sch Dent, Dept Pediat Dent Orthodont & Publ Hlth, Alameda Doutor Octavio Pinheiro Brisolla 9-75, BR-17012901 Bauru, SP - Brazil
[6] Univ Sao Paulo, Bauru Sch Dent, Dept Operat Dent Endodont & Dent Mat, Alameda Doutor Octavio Pinheiro Brisolla 9-75, BR-17012901 Bauru, SP - Brazil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: CLINICAL ORAL INVESTIGATIONS; v. 25, n. 4 AUG 2020.
Citações Web of Science: 0
Resumo

Objectives To evaluate the marginal adaptation and internal space of crowns produced by 4 CAD/CAM systems using microcomputed tomography (mu CT) and replica technique (RT). Materials and methods Monolithic lithium disilicate crowns were milled (Ceramill, Cerec, EDG, and Zirkonzahn) (n= 10). The cement film obtained with low viscosity silicone was scanned by the mu CT system and captured by a stereomicroscope, according to RT. Two-way ANOVA followed by Tukey's test were used for statistical analysis (alpha= 0.05). A uniformity index (UI) was idealized to describe the distribution of crowns' internal space and submitted to the Kruskal-Wallis and Tukey's test (alpha= 0.05). The correlation between mu CT and RT was performed by Pearson's Correlation Coeficient (alpha = 0.05). Results Marginal adaptation and internal space were statistically significant different between the experimental groups for the mu CT and RT (p< 0.05). The medians of the 4 systems tested were within clinically acceptable range and the mean (+/- SD) highest marginal discrepancy was recorded in the Ceramill group at 133.0 +/- 71.5 mu m (mu CT) and 90.6 +/- 38.5 mu m (RT). For internal fit, the UI disclosed a better distribution of the internal space for the Zirkonzahn group (p< 0.001). There was a strong correlation between the methods (p= 0.01 andr= 0.69). (AU)

Processo FAPESP: 13/10021-5 - Confiabilidade, modos de falha e adaptação de coroas protéticas unitárias
Beneficiário:José Henrique Rubo
Modalidade de apoio: Auxílio à Pesquisa - Regular