Comparison of a 3-hole 4.5-mm Dynamic Compression Plate and a 7-hole 5.5-mm Y Locking Compression Plate for Arthrodesis of the Proximal Interphalangeal Joint in Horses-an Ex Vivo Biomechanical Study

Texto completo
Autor(es):
Salazar Latorre, Carlos Adolfo [1] ; de Souza, Anderson Fernando [1] ; Ramirez Ramos, Paula Andrea [2] ; Nobrega, Fernanda Silveira [1] ; Mulder van de Graaf, Guilherme Maia [1] ; Martins Pereira, Cesar Augusto [3] ; Auada Ferrigno, Cassio Ricardo [1] ; Hendrickson, Dean A. [4] ; do Valle De Zoppa, Andre Luis [1]
Número total de Autores: 9
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Sch Vet Med & Anim Sci, Dept Surg, Ave Prof Dr Orlando Marques de Paiva 87, BR-05508270 Sao Paulo, SP - Brazil
[2] Univ Sao Paulo, Sch Vet Med & Anim Sci, Dept Internal Med, Sao Paulo, SP - Brazil
[3] Univ Sao Paulo, Sch Med, Dept Orthoped & Traumatol, Sao Paulo - Brazil
[4] Colorado State Univ, Dept Clin Sci, Ft Collins, CO 80523 - USA
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: Journal of Equine Veterinary Science; v. 94, NOV 2020.
Citações Web of Science: 0
Resumo

The objective of this study was to compare the biomechanical properties in a single cycle axial loading test and the types of failures in two constructs (a 3-hole 4.5-mm dynamic compression plate (DCP) and 7-hole 5.5-mm Y locking compression plate (Y-LCP)) in equine proximal interphalangeal joint (PIJ) arthrodesis. One limb in each pair was randomly assigned to PIJ arthrodesis using a 3-hole 4.5-mm DCP combined with two transarticular 5.5-mm cortical screws, whereas the contralateral limb was submitted to PIJ arthrodesis using a 7-hole Y-shaped 5.0-mm LCP in conjunction with one transarticular 4.5-mm cortical screw inserted through the central plate hole. Cortical screws were inserted in lag fashion. Constructs were submitted to a single axial load cycle to failure. Construct stiffness, load, and deformation were analyzed. Dynamic compression plate and Y-LCP arthrodesis constructs did not differ significantly and were equally resistant to axial loading under the conditions studied (DCP and Y-LCP group stiffness, 5685.22 N/mm and 6591.10 N/mm, respectively). Arthrodesis of the PIJ using a DCP and two transarticular 5.5-mm cortical screws or a Y-LCP yielded biomechanically equivalent outcomes under the test conditions considered. However, Y-LCP provides less impact in the palmar/plantar bone. Application of Y-LCP with unicortical screws has equivalent biomechanical characteristics of DCP and may be a safe option for PIJ arthrodesis, where potential trauma secondary to applying bicortical screws in the palmar/plantar aspect of the pastern can be avoided. (C) 2020 Elsevier Inc. All rights reserved. (AU)

Processo FAPESP: 11/13913-9 - Artrodese da articulação interfalangeana proximal de equinos: avaliação biomecânica comparativa da técnica com placa de compressão dinâmica de 4.5mm e dois parafusos oblíquos transarticulares de 5.5mm e placa em "Y" de compressão bloqueada de 5.0 m
Beneficiário:André Luis do Valle de Zoppa
Modalidade de apoio: Auxílio à Pesquisa - Regular