Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Calibration strategies for determination of Pb content in recycled polypropylene from car batteries using laser-induced breakdown spectroscopy (LIBS)

Texto completo
Autor(es):
Costa, Vinicius Camara [1] ; de Mello, Matheus Lima [2] ; Babos, Diego Victor [2] ; Castro, Jeyne Pricylla [2] ; Pereira-Filho, Edenir Rodrigues [2]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Fed Espirito Santo, Chem Dept, Spectrometry Atom Lab LEA LabPetro, BR-29075910 Vitoria, ES - Brazil
[2] Univ Fed Sao Carlos, Chem Dept, Grp Appl Instrumental Anal, BR-13565905 Sao Carlos, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Microchemical Journal; v. 159, DEC 2020.
Citações Web of Science: 0
Resumo

This study is dedicated to the evaluation of different calibration strategies applied to solid sample analysis by laser-induced breakdown spectroscopy (LIBS). The calibration strategies evaluated were partial least squares (PLS), principal component regression (PCR) and two-point calibration transfer (TP CT). The proposed calibration strategies were used for determination of lead (Pb) in recycled polypropylene from car batteries. The % trueness values were calculated comparing the predicted concentrations for PLS, PCR and TP CT and the reference concentrations obtained by inductively coupled plasma optical emission spectrometry (ICP OES). For PLS, the trueness value ranged from 74 to 139%, for PCR ranged from 74 to 123% and for TP CT ranged from 100 to 127%, showing in general the good predictive capacity of the proposed strategies. The relative standard deviation (%RSD) values ranged from 3 to 37% (PLS), from 5 to 30% (PCR) and from 6 to 21% (TP CT). In general, the values of % trueness and %RSD for TP CT strategy presented better results. The calibration strategies proposed in this study is highly compatible with LIBS, and it may contribute to minimizing matrix effects in direct solid analysis in complex samples as polymers. (AU)

Processo FAPESP: 19/24223-5 - Calibração empregando Laser-Induced Breakdown Spectroscopy (LIBS): alternativas, desafios, comparação das propostas existentes e proposição de um procedimento universal
Beneficiário:Edenir Rodrigues Pereira Filho
Modalidade de apoio: Auxílio à Pesquisa - Regular