Single geometry abutment for narrow and extra-narrow implant systems: Survival and failure modes

Texto completo
Autor(es):
Gutierres, Eliezer ; Bergamo, Edmara Tatiely Pedroso ; Carvalho, Laura Firmo ; Coelho, Paulo G. ; Campos, Tiago Moreira Bastos ; Piza, Mariana Miranda de Toledo ; Lopes, Adolfo Coelho de Oliveira ; Jalkh, Ernesto Byron Benalcazar ; Bonfante, Estevam Augusto
Número total de Autores: 9
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS; v. 143, p. 9-pg., 2023-05-16.
Resumo

The use of identical prosthetic components for all implant diameters could reduce the production costs by companies and the complexity of component selection for the clinician and his team. However, it would imply in reduction of thickness of the cervical walls of tapered internal connection implants, which could compromise the reliability of narrow and extra-narrow implants. Therefore, this study aims to evaluate the probability of survival and failure modes of extra-narrow implant systems with the same internal diameter as standard-diameter implants using the same prosthetic components. It was used eigth different implant system configurations, including narrow (o 3.3 mm) (N) extra-narrow (o 2.9 mm) (EN) and extra-narrow-scalloped (o 2.9 mm) (ENS) implants, both with cementable abutments (Ce) or titanium bases (Tib) and one-piece implants (o 2.5 mm and o 3.0 mm) (OP) (Medens, Itu, SP, Brazil), comprising the following groups: OP 3.0; OP 2.5; N Ce; N Tib; EN Ce, EN Tib, ENS-Ce and ENS-Tib. The implants were embedded using polymethylmethacrylate acrylic resin in a 15 mm matrix. Standardized maxillary central incisor crowns were virtually designed and milled to fit on the different studied abutments and cemented using a dual self-adhesive resin cement. The specimens were submitted to SSALT (Step Stress Accelerated Life Testing) at 15 Hz in water until failure or suspension of the test, until a maximum load of 500 N. Fractographic analysis of the failed specimens were realized in scanning electron microscopy. All implant systems demonstrated high probability of survival (90-100%) for missions at 50 and 100 N and values of characteristic strength superior to 139 N. Failure modes were restricted to the abutment in all the implant configurations tested. Therefore, the use extra-narrow implants with standardized prosthetic components for different implant diameters is a viable option for the replacement of anterior teeth. (AU)

Processo FAPESP: 21/06730-7 - Rumo à zircônia sustentável reciclada a partir do descarte de usinagem e melhorada por infiltração graduada e ao desenvolvimento de blocos de zircônia multicamada resistentes, graduados, e não suscetíveis ao envelhecimento
Beneficiário:Estevam Augusto Bonfante
Modalidade de apoio: Auxílio à Pesquisa - Jovens Pesquisadores - Fase 2
Processo FAPESP: 19/08693-1 - Compósitos experimentais à base de alumina e zircônia infiltrados por vidro: caracterização microestrutural e das propriedades ópticas e mecânicas.
Beneficiário:Edmara Tatiely Pedroso Bergamo
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 22/07157-1 - Caracterização física e mecânica de um sistema multicamadas utilizando zircônia reciclada
Beneficiário:Ernesto Byron Benalcazar Jalkh
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 20/12874-9 - Infiltração gradada por vidro em um compósito experimental à base de whiskers de alumina e zircônia: desenvolvimento, caracterização microestrutural e das propriedades ópticas e mecânicas
Beneficiário:Tiago Moreira Bastos Campos