Busca avançada
Ano de início
Entree


Evaluation of contiguous implants with cement-retained implant-abutment connections. A minipig study

Texto completo
Autor(es):
Martins De Barros, Raquel Rezende ; Novaes Junior, Arthur Belem ; Papalexiou, Vula ; Luczyszyn, Sonia Mara ; Papalexiou Neto, Stylianos Nicolas ; Garcez Ramos, Cassiana Maria ; Goncalves De Almeida, Adriana Luisa ; Piattelli, Adriano ; Assenza, Bartolomeo
Número total de Autores: 9
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF OSSEOINTEGRATION; v. 6, n. 1, p. 8-pg., 2014-01-01.
Resumo

Aim The presence of a microgap at the implant-abutment interface may permit bacterial contamination and lead to bone resorption, interfering with papillae formation. The present study evaluated adjacent implants with cement-retained abutments as an option to control such deleterious effects. Materials and methods Seven minipigs had their bilateral mandibular premolars previously extracted. After 8 weeks, four implants were installed in each hemi-mandible of each animal. The adjacent implants were randomly inserted on one side at the crestal bone level and on the other, 1.5 mm subcrestally. Immediately, a non-submerged healing and functional loading were provided with the abutments cementation and prostheses installation. Clinical examination and histomorphometry served to analyze the implant success. Results A total of 52 implants were evaluated at the end of the study. The subcrestal group achieved statistical better results when compared to the crestal group, clinically in papillae formation (1.97 x 1.57 mm) and histomorphometrically in crestal bone remodeling (1.17 x 1.63 mm), bone density (52.39 x 45.22%) and bone-implant contact (54.13 x 42.46%). Conclusion The subcrestal placement of cement-retained abutment implants showed better indexes of osseointegration and also improved papillae formation and crestal bone remodeling at the interimplant area after immediate loading, making them a promising option for the treatment of esthetic regions. (AU)

Processo FAPESP: 10/19737-5 - Comportamento de implantes adjacentes com pilares protéticos cimentados quanto à osseointegração, remodelamento da crista óssea e formação de papilas: avaliações clínica, radiográfica, histomorfométrica e nanomecânica em minipigs
Beneficiário:Arthur Belem Novaes Junior
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 10/19035-0 - Utilização de uma nova técnica nanomecânica para avaliação do comportamento de implantes adjacentes com pilares protéticos cimentados. Estudo em minipigs
Beneficiário:Raquel Rezende Martins de Barros
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado