Modeling and experimental study of nucleate boiling on a vertical array of horizontal plain tubes

Texto completo
Autor(es):
Ribatski, Gherhardt [1] ; Saiz Jabardo, Jose M. [2] ; Fockink da Silva, Evandro [3]
Número total de Autores: 3
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, EESC, Dept Mech Engn, Sao Carlos, SP - Brazil
[2] Univ A Coruna, Escola Politecn Super, Ferrol 15403, Coruna - Spain
[3] Ctr Fed Educ Tecnol Minas Gerais CEFETMG, Unidade Divinopolis, Divinopolis, MG - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: EXPERIMENTAL THERMAL AND FLUID SCIENCE; v. 32, n. 8, p. 1530-1537, SEP 2008.
Citações Web of Science: 23
Resumo

An investigation of nucleate boiling on a vertical array of horizontal plain tubes is presented in this paper. Experiments were performed with refrigerant RI 23 at reduced pressures varying from 0.022 to 0.64, tube pitch to diameter ratios of 1.32, 1.53 and 2.00, and heat fluxes from 0.5 to 40 kW/m(2). Brass tubes with external diameters of 19.05 mm and average roughness of 0.12 mu m were used in the experiments. The effect of the tube spacing on the local heat transfer coefficient along the tube array was negligible within the present range of experimental conditions. For partial nucleate boiling, characterized by low heat fluxes, and low reduced pressures, the tube positioning shows a remarkable effect on the heat transfer coefficient. Based on these data, a general correlation for the prediction of the nucleate boiling heat transfer coefficient on a vertical array of horizontal tubes under flooded conditions was proposed. According to this correlation, the ratio between the heat transfer coefficients of a given tube and the lowest tube in the array depends only on the tube row number, the reduced pressure and the heat flux. By using the proposed correlation, most of the experimental heat transfer coefficients obtained in the present study were predicted within +/- 15%. The new correlation compares reasonably well with independent data from the literature. (C) 2008 Elsevier Inc. All rights reserved. (AU)

Processo FAPESP: 06/52089-1 - Estudo teorico experimental da ebulicao convectiva de refrigerantes halogenados no interior de micro canais.
Beneficiário:Gherhardt Ribatski
Modalidade de apoio: Bolsas no Brasil - Jovens Pesquisadores