Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Early peri-implant endosseous healing of two implant surfaces placed in surgically created circumferential defects. A histomorphometric and fluorescence study in dogs

Texto completo
Autor(es):
Martins de Barros, Raquel Rezende [1] ; Novaes, Jr., Arthur Belem [1] ; Queiroz, Adriana [1] ; Goncalves de Almeida, Adriana Luisa [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Ribeirao Preto Dent Sch, Dept Oral & Maxillofacial Surg & Traumatol & Peri, BR-14040904 Ribeirao Preto, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Clinical Oral Implants Research; v. 23, n. 12, p. 1340-1351, DEC 2012.
Citações Web of Science: 5
Resumo

Objective Several implant surfaces are being developed, some in the nanoscale level. In this study, two different surfaces had their early healing properties compared in context of circumferential defects of various widths. Material and methods Six dogs had the mandibular premolars extracted. After 8weeks, four implants were placed equicrestally in each side. One acted as control, while the others were inserted into sites with circumferential defects of 1.0, 1.5 and 2.0mm wide and 5mm deep. A nano-modified surface was used on one side and a micro-rough on the other. Bone markers were administered on the third day after implant placement and then after 1, 2, 4weeks to investigate the bone formation dynamic through fluorescence analysis. Ground sections were prepared from 8-week healing biopsies and histomorphometry was performed. Results The fluorescence evaluation of the early healing showed numerically better results for the nano-modified group; however this trend was not followed by the histomorphometric evaluation. A non-significant numerical superiority of the micro-rough group was observed in terms of vertical bone apposition, defect bone fill, bone-to-implant contact and bone density. In the intra-group analysis, the wider defects showed the worse results while the control sites showed the best results for the different parameters, but without statistical relevance. Conclusion Both surfaces may lead to complete fill of circumferential defects, but the gap width has to be considered as a challenge. The nano-scale modification was beneficial in the early stages of bone healing, but the micro-rough surface showed numerical better outcomes at the 8-week final period. (AU)

Processo FAPESP: 06/56020-6 - Superfície de implante bioativa - parte I: efeito de superfície de implante bioativa na osseointegração e nas dinâmicas de cicatrização óssea. Estudo histomorfométrico em cães - parte II: pode uma superfície de implante bioativa melhorar a capacidade óssea de jumping gap?
Beneficiário:Arthur Belem Novaes Junior
Modalidade de apoio: Auxílio à Pesquisa - Regular