Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Evaluation of the effective energy of primary and transmmitted workload weighted X-ray spectra

Texto completo
Autor(es):
Santos, J. C. [1] ; Costa, P. R. [1]
Número total de Autores: 2
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Inst Fis, Dept Fis Nucl, BR-05508090 Sao Paulo - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Radiation Physics and Chemistry; v. 95, p. 221-223, FEB 2014.
Citações Web of Science: 5
Resumo

Current methods for X-ray shielding evaluation for imaging facilities do not take into account the effective energy of the radiation impinging on primary barrier. In addition, the X-ray beam attenuation through the patient is not considered in radiation shielding. The proposed models do not deal with the hardening of the spectra between the primary and transmitted beams. Therefore, the present work proposes the evaluation of X-ray spectra transmitted by an adult patient (anthropomorphic phantom) and a shielding barrier weighted by typical workload distributions. A set of primary spectra produced by a voltage range from 60 to 140 kV was measured with a CdTe spectrometer system. A second set of X-ray spectra transmitted through a 15 mm thickness barite mortar plate was also measured employing the same beam quality and voltage range. The air-kerma was simultaneously measured using an ionization chamber. The primary and transmitted experimental X-ray spectra were weighted by a typical chest examination workload distribution. The resulting weighted spectra represent the superposition of the radiation beams typically used in chest examinations. The effective energy of primary weighted spectra was estimated in 42.4 keV and the effective energy of the corresponding transmitted spectra was estimated in 64.7 keV. (C) 2013 Elsevier Ltd. All rights reserved. (AU)

Processo FAPESP: 11/04721-9 - Estudo experimental das relações entre kerma no ar e equivalente de dose ambiente para o cálculo de barreiras primárias em salas radiológicas
Beneficiário:Josilene Cerqueira Santos
Modalidade de apoio: Bolsas no Brasil - Mestrado
Processo FAPESP: 10/12237-7 - Estudo experimental das relações entre Kerma no ar e equivalente de dose ambiente para o cálculo de barreiras primárias em salas radiológicas
Beneficiário:Paulo Roberto Costa
Modalidade de apoio: Auxílio à Pesquisa - Regular