Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

A versatile and robust electrochemical flow cell with a boron-doped diamond electrode for simultaneous determination of Zn2+ and Pb2+ ions in water samples

Texto completo
Autor(es):
dos Santos, Vagner Bezerra [1] ; Fava, Elson Luiz [1] ; Pessoa-Neto, Osmundo Dantas [1] ; Bianchi, Silmara Rossana [2] ; Faria, Ronaldo Censi [1] ; Fatibello-Filho, Orlando [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Fed Sao Carlos, Ctr Ciencias Exatas & Tecnol, Dept Quim, BR-13565905 Sao Carlos, SP - Brazil
[2] Embrapa Solos, Empresa Brasileira Pesquisa Agr, Rio De Janeiro, RJ - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: ANALYTICAL METHODS; v. 6, n. 21, p. 8526-8534, NOV 7 2014.
Citações Web of Science: 12
Resumo

A versatile and robust thermostatted electrochemical flow cell (EFC) with a boron-doped diamond electrode (BDD) detector was employed to perform two distinct flow-injection electrochemical approaches. In the first approach, differential pulse anodic stripping voltammetry (DPASV) using a flow-batch analysis (FBA) is proposed. In the second approach, multiple pulse amperometry (MPA) employing multicommutation flow analysis (MCFA) is also presented. Both approaches were employed to simultaneously determine Zn2+ and Pb2+ in water samples. For this, a screen-printed electrode (SPE) was developed, and a BDD electrode was coupled to it and was inserted into the EFC. By employing the FBA with the DPASV technique, two analytical curves in concentration ranges from 11.5 to 80.6 mu g L-1 and 0.64 to 10.9 mu g L-1 for simultaneous determination of Zn2+ and Pb2+, respectively, were obtained. Moreover, limits of detection (LDs) of 0.62 mu g L-1 and 0.19 mu g L-1 were estimated respectively and a sampling frequency of 12 h(-1) was obtained. For MCFA with MPA, analytical curves from 830 to 4980 mu g L-1 and 140 to 820 mu g L-1 for simultaneous determination of Zn2+ and Pb2+ with LDs of 220.0 mu g L-1 and 41.0 mu g L-1 and a sampling frequency of 67 h(-1) were obtained. The developed EFC allowed a full on-line automation of the methods, covering the pretreatment of BDD, addition of standard solutions, dilutions, thermostatted control, and detection with and without electrochemical preconcentration. In addition, the low waste generation of only 700 mu L may be useful for green chemistry purposes and sustainable research. (AU)

Processo FAPESP: 10/11690-0 - Desenvolvimento e aplicação de um potenciostato /galvanostato microprocessado portátil para o monitoramento in situ e on-line de íons metálicos em amostras ambientais
Beneficiário:Orlando Fatibello Filho
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 13/14993-1 - Caracterização e quantificação de monoalquil carbonatos em meio aquoso empregando dispositivos microfluídicos acoplado a um espectrômetro de massas
Beneficiário:Vagner Bezerra dos Santos
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 11/23598-3 - Desenvolvimento e aplicação de um potenciostato/galvanostato microprocessado portátil para o monitoramento in situ e on-line de íons metálicos em amostras ambientais
Beneficiário:Elson Luiz Fava
Modalidade de apoio: Bolsas no Brasil - Programa Capacitação - Treinamento Técnico