Surface Damage on Dental Implants with Release of ... - BV FAPESP
Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Surface Damage on Dental Implants with Release of Loose Particles after Insertion into Bone

Texto completo
Autor(es):
Senna, Plinio [1] ; Cury, Altair Antoninha Del Bel [1] ; Kates, Stephen [2] ; Meirelles, Luiz [3]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Campinas, SP - Brazil
[2] Univ Rochester, Dept Orthopaed, Rochester, NY 14620 - USA
[3] Univ Rochester, Eastman Dent Ctr, Div Prosthodont, Rochester, NY 14620 - USA
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH; v. 17, n. 4, p. 681-692, AUG 2015.
Citações Web of Science: 17
Resumo

BackgroundModern dental implants present surface features of distinct dimensions that can be damaged during the insertion procedure into bone. PurposeThe aims of this study were (1) to quantify by means of roughness parameters the surface damage caused by the insertion procedure of dental implants and (2) to investigate the presence of loose particles at the interface. Materials and MethodsThree groups of dental implants representing different surface topographies were inserted in fresh cow rib bone blocks. The surface roughness was characterized by interferometry on the same area before and after the insertion. Scanning electron microscopy (SEM)-back-scattered electron detector (BSD) analysis was used to identify loose particles at the interface. ResultsThe amplitude and hybrid roughness parameters of all three groups were lower after insertion. The surface presenting predominance of peaks (S-sk {[}skewness]>0) associated to higher structures (height parameters) presented higher damage associated to more pronounced reduction of material volume. SEM-BSD images revealed loose titanium and aluminum particles at the interface mainly at the crestal cortical bone level. ConclusionsShearing forces during the insertion procedure alters the surface of dental implants. Loose metal particles can be generated at bone-implant interface especially around surfaces composed mainly by peaks and with increased height parameters. (AU)

Processo FAPESP: 11/23269-0 - Caracterização da superfície do titânio nitretado por plasma a frio e avaliação in vivo da adição de diferentes nanopartículas bioativas em implantes com diferentes rugosidades
Beneficiário:Plinio Mendes Senna
Modalidade de apoio: Bolsas no Exterior - Estágio de Pesquisa - Doutorado