Laser-induced breakdown spectroscopy: Extending its application to soil pH measurements

Texto completo
Autor(es):
Ferreira, Edilene Cristina [1] ; Gomes Neto, Jose A. [1] ; Milori, Debora M. B. P. [2] ; Ferreira, Ednaldo Jose [2] ; Manuel Anzano, Jesus [3]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Sao Paulo State Univ UNESP, Dept Analyt Chem, BR-14800060 Araraquara, SP - Brazil
[2] Embrapa Agr Instrumentat, BR-13560970 Sao Carlos, SP - Brazil
[3] Univ Zaragoza, Fac Sci, Laser Lab & Environm, E-50009 Zaragoza - Spain
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY; v. 110, p. 96-99, AUG 1 2015.
Citações Web of Science: 19
Resumo

Acid-base equilibria are involved in almost all the processes that occur in soil. The bioavailability of nutrients for plants, for instance, depends on the solubilization of mineral nutrients in the soil solution, which is a pH-dependent process. The determination of pH in soil solutions is usually carried out by potentiometry using a glass membrane electrode, after extracting some of the soil components with water or CaCl2 solution. The present work describes a simple method for determining the pH of soil, using laser-induced breakdown spectroscopy (LIBS). Sixty samples presenting different textural composition and pH (previously determined by potentiometry) were employed. The samples were divided into a calibration set with fifty samples and a validation set with ten samples. LIBS spectra were recorded for each pelleted sample using laser pulse energy of 115 mJ. The intensities of thirty-two emission lines for Al, Ca, H, and O were used to fit a partial least squares (PLS) model. The model was validated by prediction of the pH of the validation set samples, which showed good agreement with the reference values. The prediction mean absolute error was 0.3 pH units and the root mean square error of the prediction was 0.4. These results highlight the potential of LIBS for use in other applications beyond elemental composition determinations. For soil analysis, the proposed method offers the possibility of determining pH, in addition to nutrients and contaminants, using a single LIBS measurement (C) 2015 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 06/61741-4 - Avaliacao de sistema libs portatil para analise de solos.
Beneficiário:Edilene Cristina Ferreira
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 14/26185-0 - Pittcon Conference & Expo 2015
Beneficiário:Edilene Cristina Ferreira
Modalidade de apoio: Auxílio à Pesquisa - Reunião - Exterior