Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Implant retainers for free-end removable partial dentures affect mastication and nutrient intake

Texto completo
Autor(es):
Campos, Camila Heitor [1] ; Vega Goncalves, Thais Marques Simek [1] ; Matheus Rodrigues Garcia, Renata Cunha [1]
Número total de Autores: 3
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, BR-13414903 Piracicaba, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Clinical Oral Implants Research; v. 25, n. 8, p. 957-961, AUG 2014.
Citações Web of Science: 11
Resumo

Objectives: This study measured swallowing threshold parameters and nutrient intake in partially dentate subjects rehabilitated by conventional free-end removable partial dentures (RPD) and by RPD over posterior implant retainers and ball attachments (BA). Materials and methods: Eight subjects (two men and six women; mean age 60.1 +/- 6.6 years old) received conventional total maxillary dentures and free-end RPD in the mandible. Two months after denture insertion, swallowing threshold and nutrient intake assessments occurred, which included an evaluation of the number of masticatory cycles and medium particle size (X-50) of a silicone test material (Optocal). A 3-day food diary verified nutrient intake based on a standard Brazilian Food Composition Table. Then, osseointegrated implants were placed bilaterally in the mandibular first molar region, followed by BA, which was fitted in the RPD bases after healing. After 2 months of the RPD over implants and BA use, variables were again assessed. Wilcoxon signed rank tests evaluated the data (P < 0.05). Results: Masticatory cycles did not differ (P > 0.05); however, subjects showed decreased X-50 values at the swallowing moment (P = 0.008) and increased daily energy (P = 0.008), carbohydrate (P = 0.016), protein (P = 0.023), calcium (P = 0.008), fiber (P = 0.016), and iron (P = 0.016) intake with RPD implants and BA inserts. No differences were found in fat consumption (P > 0.05). Conclusion: Implants and BA retainers over a free-end RPD resulted in smaller swallowed median particle size and improved nutrient intake. (AU)

Processo FAPESP: 10/12251-0 - Função mastigatória, qualidade de vida e estado nutricional de pacientes reabilitados por próteses removíveis e fixas sobre implantes osseointegrados
Beneficiário:Renata Cunha Matheus Rodrigues Garcia
Modalidade de apoio: Auxílio à Pesquisa - Regular