Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Br isotope determination via the monitoring of CaBr transitions using high-resolution continuum source graphite furnace molecular absorption spectrometry. Potential for direct determination of Br in solid samples using isotope dilution

Texto completo
Autor(es):
Nakadi, F. V. [1] ; da Veiga, M. A. M. S. [1] ; Aramendia, M. [1, 2] ; Garcia-Ruiz, E. [1] ; Resano, M. [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Zaragoza, Aragon Inst Engn Res I3A, Dept Analyt Chem, Pedro Cerbuna 12, E-50009 Zaragoza - Spain
[2] Acad Gen Mil Zaragoza, Ctr Univ Def, Carretera Huesca S-N, Zaragoza 50090 - Spain
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Journal of Analytical Atomic Spectrometry; v. 31, n. 7, p. 1381-1390, 2016.
Citações Web of Science: 9
Resumo

This work investigates the possibility of obtaining Br isotopic information by generating a gaseous diatomic molecule in a graphite furnace and monitoring its absorption spectrum using a high-resolution continuum source device (HR CS GFMAS). Different metals (Al, Ba, and Ca) were investigated to produce this diatomic molecule and the most promising results, both in terms of isotopic shift and sensitivity, were obtained with Ca, thus leaving CaBr as the target species. The results demonstrate that, unlike what occurs when monitoring atomic spectra, which are characterized by very small isotopic shifts that can hardly be detected, using HR CS GFMAS it is feasible to observe several molecular transitions corresponding to (CaBr)-Br-79 and (CaBr)-Br-81 that are spectrally resolved (i.e. they act like two different molecules absorbing at different wavelengths), and can be simultaneously quantified. The method developed relies on the addition of both Pd and Ca (as a chemical modifier and molecule forming agent, respectively), the selection of peak height values and the use of IBC-m (iterative baseline correction for the monitoring of molecules) for setting the baseline. This method enables accurate Br isotopic analysis in 10 mg L-1 solutions with precision values around 2.5% RSD, without requiring any method for mass bias correction. Moreover, it is also demonstrated how the use of isotope dilution for calibration can help in circumventing severe chemical interferences (e.g., deriving from the presence of high amounts of Cl) when aiming at the direct determination of Br in solid samples by HR CS GFMAS. The accuracy of the method was evaluated via analysis of two different reference materials, poly(vinyl chloride) and tomato leaves. (AU)

Processo FAPESP: 14/24430-7 - Avaliação da análise por diluição isotópica na determinação de bromo por espectrometria de absorção molecular de alta resolução com fonte contínua em forno de grafite
Beneficiário:Márcia Andreia Mesquita Silva da Veiga
Modalidade de apoio: Bolsas no Exterior - Pesquisa