Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do SciELO, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Correlation between ultrasound velocity and densitometry in fresh and demineralized cortical bone

Texto completo
Autor(es):
Alessandro Queiroz de Mesquita [1] ; Giuliano Barbieri [2] ; Claudio Henrique Barbieri [3]
Número total de Autores: 3
Afiliação do(s) autor(es):
[1] Universidade de São Paulo. Departamento de Biomecânica. Medicina e Reabilitação do Aparelho Locomotor - Brasil
[2] Universidade de São Paulo. Departamento de Biomecânica. Medicina e Reabilitação do Aparelho Locomotor - Brasil
[3] Universidade de São Paulo. Departamento de Biomecânica. Medicina e Reabilitação do Aparelho Locomotor - Brasil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Clinics; v. 71, n. 11, p. 657-663, 2016-11-00.
Resumo

OBJECTIVE: To compare ultrasound propagation velocity with densitometry in the diaphyseal compact cortical bone of whole sheep metatarsals. METHODS: The transverse ultrasound velocity and bone mineral density of 5-cm-long diaphyseal bone segments were first measured. The bone segments were then divided into four groups of 15 segments each and demineralized in an aqueous 0.5 N hydrochloric acid solution for 6, 12, 24 or 36 hours. All measurements were repeated after demineralization for each time duration and the values measured before and after demineralization were compared. RESULTS: Ultrasound velocity and bone mineral density decreased with demineralization time, and most differences in the pre- and post-demineralization values within each group and between groups were significant: A moderate correlation coefficient (r=0.75956) together with a moderate agreement was determined between both post-demineralization parameters, detected by the Bland-Altman method. CONCLUSION: We conclude that both ultrasound velocity and bone mineral density decrease as a result of demineralization, thus indicating that bone mineral content is of great importance for maintaining the acoustic parameters of cortical bone, as observed for cancellous bone. Ultrasound velocity can be used to evaluate both compact cortical bone quality and bone mineral density. (AU)

Processo FAPESP: 09/52797-4 - Utilização do plasma rico em plaquetas autógenas nas falhas ósseas: avaliação da regeneração óssea em estudo experimental com animais
Beneficiário:Claudio Henrique Barbieri
Modalidade de apoio: Auxílio à Pesquisa - Regular