Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

MAOD Determined in a Single Supramaximal Test: a Study on the Reliability and Effects of Supramaximal Intensities

Texto completo
Autor(es):
Zagatto, A. M. ; Bertuzzi, R. ; Miyagi, W. E. ; Padulo, J. ; Papoti, M.
Número total de Autores: 5
Tipo de documento: Artigo Científico
Fonte: INTERNATIONAL JOURNAL OF SPORTS MEDICINE; v. 37, n. 9, p. 700-707, AUG 2016.
Citações Web of Science: 16
Resumo

The main barrier to the wide use of maximal accumulated oxygen deficit (MAOD) is the considerable time required to apply several sub-and supra-maximal exercise sessions. The main question of this study was whether the determination of MAOD using a single supramaximal exercise session (MAOD(ALT)) is valid and reliable in running. We investigated the effects of the supramaximal exercise intensity (A) and the reliability of a single supramaximal exercise session (B) to assess MAOD in treadmill running. For this aim 29 subjects participated in A \& B studies with single allocation ``A{''} (n = 15) and ``B{''} (n = 14). The conventional MAOD and 8 MAOD(ALT) were determined in exhaustive efforts varying between 100-150 % at an intensity associated with maximal oxygen uptake (i(V) over dotO(2MAX)). In B study 2 supramaximal efforts were applied to analyze the test-retest reliability. Non-significant differences were found between MAOD and the 8 values of MAOD(ALT). Despite the MAOD being statistically correlated with the MAOD(ALT) 100 % i(V) over dotO(2MAX) (0.49 < r > 0.59), MAOD(ALT) determined at 115 % of i(V) over dotO(2MAX) (52.4 +/- 1.7 mL.kg(-1)) presented the higher correlation values (0.65 < r > 0.77) and concordance. In addition, the MAOD at 115 % of i(V) over dotO(2MAX) presented high test-retest reliability. MAOD(ALT) determined at 115 % of i(V) over dotO(2MAX) was a valid and reliable method to assess MAOD in running. (AU)

Processo FAPESP: 14/02829-5 - Determinação do máximo déficit acumulado de oxigênio utilizando apenas uma sessão de exercício supramáximo em cicloergômetro
Beneficiário:Willian Eiji Miyagi
Modalidade de apoio: Bolsas no Brasil - Mestrado
Processo FAPESP: 13/12940-8 - Determinação do déficit máximo de oxigênio acumulado por meio de uma única sessão de esforço supramáximo: análise da reprodutibilidade, influência do ergômetro e intensidade de esforço
Beneficiário:Alessandro Moura Zagatto
Modalidade de apoio: Auxílio à Pesquisa - Regular