Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Effect of different precursors on generation of reference spectra for structural molecular background correction by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry: Determination of antimony in cosmetics

Texto completo
Autor(es):
Barros, Ariane Isis ; de Babos, Diego Victor ; Ferreira, Edilene Cristina ; Gomes Neto, Jose Anchieta
Número total de Autores: 4
Tipo de documento: Artigo Científico
Fonte: Talanta; v. 161, p. 547-553, DEC 1 2016.
Citações Web of Science: 5
Resumo

Different precursors were evaluated for the generation of reference spectra and correction of the background caused by SiO molecules in the determination of Sb in facial cosmetics by high-resolution continuum source graphite furnace atomic absorption spectrometry employing direct solid sample analysis. Zeolite and mica were the most effective precursors for background correction during Sb determination using the 217.581 nm and 231.147 nm lines. Full 2(3) factorial design and central composite design were used to optimize the atomizer temperature program. The optimum pyrolysis and atomization temperatures were 1500 and 2100 degrees C, respectively. A Pd(NO3)(2)/Mg(NO3)(2) mixture was employed as the chemical modifier, and calibration was performed at 217.581 nm with aqueous standards containing Sb in the range 0.5-2.25 ng, resulting in a correlation coefficient of 0.9995 and a slope of 0.1548 s ng(-1). The sample mass was in the range 0.15-0.25 mg. The accuracy of the method was determined by analysis of Montana Soil (II) certified reference material, together with addition/recovery tests. The Sb concentration found was in agreement with the certified value, at a 95% confidence level (paired t-test). Recoveries of Sb added to the samples were in the range 82-108%. The limit of quantification was 0.9 mg kg(-1) and the relative standard deviation (n=3) ranged from 0.5% to 7.1%. From thirteen analyzed samples, Sb was not detected in ten samples (blush, eye shadow and compact powder); three samples (two blush and one eye shadow) presented Sb concentration in the 9.1 - 14.5 mg kg(-1) range. (C) 2016 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 14/12595-1 - Avaliação da amostragem direta de sólidos aliada a espectrometria de absorção atômica com fonte contínua e de alta resolução em análises químicas de amostras de difícil solubilização
Beneficiário:José Anchieta Gomes Neto
Modalidade de apoio: Auxílio à Pesquisa - Regular