A Nanostructured Bifunctional platform for Sensing of Glucose Biomarker in Artificial Saliva: Synergy in hybrid Pt/Au surfaces

Texto completo
Autor(es):
Raymundo-Pereira, Paulo A. ; Shimizu, Flavio M. ; Coelho, Dyovani ; Piazzeta, Maria H. O. ; Gobbi, Angelo L. ; Machado, Sergio A. S. ; Oliveira, Jr., Osvaldo N.
Número total de Autores: 7
Tipo de documento: Artigo Científico
Fonte: BIOSENSORS & BIOELECTRONICS; v. 86, p. 369-376, DEC 15 2016.
Citações Web of Science: 20
Resumo

We report on a bimetallic, bifunctional electrode where a platinum (Pt) surface was patterned with nanostructured gold (Au) fingers with different film thicknesses, which was functionalized with glucose oxidase (GOx) to yield a highly sensitive glucose biosensor. This was achieved by using selective adsorption of a self-assembled monolayer (SAM) onto Au fingers, which allowed GOx immobilization only onto the Au-SAM surface. This modified electrode was termed bifunctional because it allowed to simultaneously immobilize the biomolecule (GOx) on gold to catalyze glucose, and detect hydrogen peroxide on Pt sites. Optimized electrocatalytic activity was reached for the architecture Pt/Au-SAM/GOx with 50 nm thickness of Au, where synergy between Pt and Au allowed for detection of hydrogen peroxide (H2O2) at a low applied potential (0 V vs. Ag/AgCl). Detection was performed for H2O2 in the range between 4.7 and 102.7 nmol L-1, with detection limit of 3.4 x 10(-9) mol L-1 (3.4 nmol L-1) and an apparent Michaelis-Menten rate constant of 3.2 x 10(-6) mol L-1, which is considerably smaller than similar devices with monometallic electrodes. The methodology was validated by measuring glucose in artificial saliva, including in the presence of interferents. The synergy between Pt and Au was confirmed in electrochemical impedance spectroscopy measurements with an increased electron transfer, compared to bare Pt and Au electrodes. The approach for fabricating the reproducible bimetallic Pt/Au electrodes is entirely generic and may be explored for other types of biosensors and biodevices where advantage can be taken of the combination of the two metals. (C) 2016 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 13/14262-7 - Filmes nanoestruturados de materiais de interesse biológico
Beneficiário:Osvaldo Novais de Oliveira Junior
Modalidade de apoio: Auxílio à Pesquisa - Temático
Processo FAPESP: 12/17689-9 - Preparação e caracterização de superfícies bifuncionais nanoestruturadas de Au-Pt obtidas via template para aplicação em sensores e biossensores
Beneficiário:Paulo Augusto Raymundo Pereira
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 12/15543-7 - Biossensores para detectar Escherichia coli usando o conceito de línguas eletrônicas
Beneficiário:FLAVIO MAKOTO SHIMIZU
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado