Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

The sensitivity of the alternative maximal accumulated oxygen deficit method to discriminate training status

Texto completo
Autor(es):
Zagatto, Alessandro M. ; Nakamura, Fabio Y. ; Milioni, Fabio ; Miyagi, Willian E. ; de Poli, Rodrigo A. B. ; Padulo, Johnny ; Bragazzi, Nicola L. ; Papoti, Marcelo
Número total de Autores: 8
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF SPORTS SCIENCES; v. 35, n. 24, p. 2453-2460, 2017.
Citações Web of Science: 5
Resumo

The purpose of the study was to investigate the sensitivity of an alternative maximal accumulated oxygen deficit (MAOD(ALT)) method to discriminate the ``anaerobic{''} capacity while comparing: least trained (LT) participants (n = 12), moderately trained (MT) participants (n = 12), endurance trained (ET) participants (n = 16), and rugby (RG) players (n = 11). Participants underwent a graded exercise test on a treadmill and a supramaximal effort for assessing MAODALT. MAODALT was calculated as the sum of oxygen equivalents from the phosphagen and glycolytic metabolic pathways. MAODALT was significantly higher (P < 0.05) in RG (64.4 +/- 12.1 mL.kg(-1)) than in ET (56.8 +/- 5.4 mL.kg(-1); effect size {[}ES] = 0.77; + 13.5%), MT (53.8 +/- 5.3 mL.kg(-1); ES = 1.08; + 19.8%), and LT (49.9 +/- 4.5 mL.kg(-1); ES = 1.50; + 36.4%). In addition, the magnitude-based inference analysis revealed that MAODALT was likely (LT vs. MT), very likely (MT vs. RG, and ET vs. RG) and most likely (LT vs. ET, and LT vs. RG) different between all groups, except for MT and ET, which presented an unclear difference. In conclusion, MAODALT was sensitive enough to distinguish the ``anaerobic{''} capacity in individuals with different training status, especially for RG players compared with LT participants and MT participants. (AU)

Processo FAPESP: 14/02829-5 - Determinação do máximo déficit acumulado de oxigênio utilizando apenas uma sessão de exercício supramáximo em cicloergômetro
Beneficiário:Willian Eiji Miyagi
Modalidade de apoio: Bolsas no Brasil - Mestrado
Processo FAPESP: 13/12940-8 - Determinação do déficit máximo de oxigênio acumulado por meio de uma única sessão de esforço supramáximo: análise da reprodutibilidade, influência do ergômetro e intensidade de esforço
Beneficiário:Alessandro Moura Zagatto
Modalidade de apoio: Auxílio à Pesquisa - Regular