Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Cysts within Otherwise Probably Benign Solid Breast Masses and the Risk of Malignancy

Texto completo
Autor(es):
Jales, Rodrigo Menezes ; Araujo, Karla Galvao ; Zanata Sarian, Luis Otavio ; Serra, Katia Piton ; Keppke, Helena ; Francisco, Juliana ; Mauricette Derchain, Sophie Francoise
Número total de Autores: 7
Tipo de documento: Artigo Científico
Fonte: Revista Brasileira de Ginecologia e Obstetrícia; v. 38, n. 4, p. 170-176, APR 2016.
Citações Web of Science: 1
Resumo

Objective The objective of this study is to assess whether the largest cyst diameter is useful for BI-RADS ultrasonography classification of predominantly solid breast masses with an oval shape, circumscribed margins, and largest axis parallel to the skin, which, except for the cystic component, would be likely classified as benign. Methods This study received approval from the local institutional review board. From March 2009 to August 2014, we prospectively biopsied 170 breast masses from 164 women. We grouped the largest cyst and mass diameters according to histopathological diagnoses. We used Student's t-test, linear regression, and the area under the receiver operating characteristic curve (AUC) for statistical assessment. Results Histopathological examination revealed 143 (84%) benign and 27 (16%) malignant masses. The mean largest mass diameter was larger among malignant (mean +/- standard deviation, 34.1 +/- 16.6 mm) than benign masses (24.7 +/- 16.7 mm) (P < 0.008). The mean largest cyst diameter was also larger among malignant (9.9 +/- 7.1 mm) than benign masses (4.6 +/- 3.6 mm) (P < 0.001). Agreement between measurements of the largest mass and cyst diameters was low (R-2 = 0.26). AUC for the largest cyst diameter (0.78) was similar to the AUC for the largest mass diameter (0.69) (p = 0.2). A largest cyst diameter < 3, >= 3 to < 11, and >= 11 mm had a positive predictive value of 0, 15, and 52%, respectively. Conclusion A largest cystic component < 3 mm identified within breast masses that show favorable characteristics may be considered clinically inconsequential in ultrasonography characterization. Conversely, masses with a largest cystic component >= 3 mm should be classified as BI-RADS-US category 4. (AU)

Processo FAPESP: 12/15059-8 - Avaliação de biomarcadores para detecção de neoplasia maligna em mulheres com tumor anexial
Beneficiário:Sophie Françoise Mauricette Derchain
Linha de fomento: Auxílio à Pesquisa - Regular