Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Determination of the Accuracy of 5 Electronic Apex Locators in the Function of Different Employment Protocols

Texto completo
Autor(es):
Oliveira, Tiago Nepomuceno ; Vivacqua-Gomes, Nilton [1] ; Bernardes, Ricardo Affonso [2] ; Vivan, Rodrigo Ricci [3] ; Hungaro Duarte, Marco Antonio [3] ; Vasconcelos, Bruno Carvalho [4]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Sao Leopoldo Mandic Univ, Sch Dent Ceara, Fortaleza, Ceara - Brazil
[2] Brazilian Dent Assoc, Taguatinga, DF - Brazil
[3] Univ Sao Paulo, Bauru Dent Sch, Dept Dent Endodont & Dent Mat, Bauru, SP - Brazil
[4] Univ Fed Ceara, Sch Dent Sobral, Campus Sobral, BR-62010590 Sobral, Ceara - Brazil
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF ENDODONTICS; v. 43, n. 10, p. 1663-1667, OCT 2017.
Citações Web of Science: 5
Resumo

Introduction: The aim of this study was to evaluate the accuracy of 5 electronic apex locators (EALs): Root ZX II (RZX; J Morita, Tokyo, Japan), Raypex 6 (RAY; VDW GmbH, Munich, Germany), Apex ID (AID; SybronEndo, Orange, CA), Propex II (PRO; Dentsply Maillefer, Ballaigues, Switzerland), and Propex Pixi (PIXI, Dentsply Maillefer) when used in the following protocols: (1) 1.0, insertion up to 1.0 mm below the apical foramen (AF); (2) 0.0/-1.0, insertion until the AF and withdrawn 1.0 mm short of the AF; (3) 0.0, insertion until the AF; and (4) over/0.0, insertion until ``over{''} and withdrawal to AF. Methods: Thirty human lower premolars had coronary accesses and cervical and middle thirds preparations performed, allowing AF standardization (200 Am). Using an alginate experimental model, root canal length (RCL) measurements were performed sequentially with EALs following each of the protocols. Results: Considering the suggested protocols, the lowest mean error values were observed in 0.0, 0.10 mm (RZX), 0.13 mm (RAY), 0.16 mm (AID), 0.23 mm (PRO), and 0.10 mm (PIXI), without a significant difference for over/0.0 (P >.05). Comparing the results obtained in 0.0 with those found in 1.0 and 0.0/-1.0, significant differences were observed for most EALs (P <.05). For the comparison between EALs, significant differences were observed only in protocols 1.0 and over/0.0 (P <.05). Conclusions: Under the conditions of the study, it was concluded that, regardless of the mechanism of the device, the best results were found when electronic RCL measurement was performed at the AF; furthermore, the electronic withdrawal did not offer any additional advantage over the reach of the AF. (AU)

Processo FAPESP: 16/00245-1 - Avaliação das propriedades físico-químicas de um cimento experimental à base de agregado trióxido mineral, determinação de sua compatibilidade com um novo sistema de obturação, e da qualidade e estabilidade de obturações realizadas com o mesmo
Beneficiário:Bruno Carvalho de Vasconcelos
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado