Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Performance of an anaerobic baffled reactor with an aerobic chamber treating low-strength wastewater

Texto completo
Autor(es):
da Silva, Julliana Alves [1] ; Sarti, Arnaldo [2] ; Maintinguer, Sandra Imaculada [3] ; Kaiser, Ilza Machado [1] ; Ribeiro da Silva, Gustavo Henrique [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] UNESP Univ Estadual Paulista, Coll Engn, Dept Civil & Environm Engn, Bauru Fac Engn, Av Eng Luiz Edmundo Carrijo Coube 14-01, BR-17033360 Bauru, SP - Brazil
[2] UNESP Univ Estadual Paulista, Inst Chem, Dept Biochem & Chem Technol, Campus Araraquara, Rua Prof Francisco Degni 55, BR-14800900 Araraquara, SP - Brazil
[3] UNESP Univ Estadual Paulista, Inst Res Bioenergy, Campus Rio Claro, Rua 10, 2527, BR-13500230 Rio Claro, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Desalination and Water Treatment; v. 100, p. 1-10, DEC 2017.
Citações Web of Science: 3
Resumo

The objective of this study was to evaluate the performance of an anaerobic baffled reactor (ABR)with an aerobic chamber (AC) in the treatment of domestic wastewater with a low organic load (0.10 +/- 0.02 to 0.51 +/- 0.10 kg COD.m(-3).d(-1)). The entire system consisted of three anaerobic chambers (C1, C2, C3), one aerobic chamber (AC) and one laminar settling tank (LST), operated for 30 weeks (203 d) with different total hydraulic retention times (HRT) of 33, 22, 16.5, and 8.25 h. During the operation of the system, the values of COD of the influent varied between 105 and 381 mg.L-1 and the effluent varied between 12 and 147 mg.L-1, with average concentrations of 214 +/- 63 mg.L-1 in the influent and 48 +/- 25 mg.L-1 in the effluent. Considering the entire system (ABR + AC + LST), the values of total removal efficiency for COD varied between 49 and 92%, with an average removal of 78 +/- 9%. No accumulation of volatile fatty acids (VFA) was found, as the VFA concentration remained between 32 and 76 mg HAc.L-1 at the influent and between 21 and 53 mg HAc.L-1 at C3. Bio molecular analyses showed a great variety of bacterial communities established in all phases of monitoring and low archaeal community diversity. The combined configuration (ABR + AC) has shown great potential for the treatment of domestic wastewater, thereby being considered as a promising alternative for decentralized treatment. (AU)

Processo FAPESP: 11/10816-2 - Desinfecção de efluentes utilizando cloro, ozônio, ozônio/cloro e ozônio/peróxido de hidrogênio
Beneficiário:Gustavo Henrique Ribeiro da Silva
Modalidade de apoio: Auxílio à Pesquisa - Regular