Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Stability of the Light Output, Oral Cavity Tip Accessibility in Posterior Region and Emission Spectrum of Light-Curing Units

Texto completo
Autor(es):
Andre, C. B. [1] ; Nima, G. [2] ; Sebold, M. [1] ; Giannini, M. [3] ; Price, R. B. [4]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Restorat Dent, Piracicaba - Brazil
[2] Univ Estadual Campinas, Piracicaba Dent Sch, Dent Mat, Piracicaba - Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Piracicaba - Brazil
[4] Dalhousie Univ, Dent Clin Sci, Halifax, NS - Canada
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: Operative Dentistry; v. 43, n. 4, p. 398-407, JUL-AUG 2018.
Citações Web of Science: 5
Resumo

Objectives: This study evaluated the light output from six light-emitting diode dental curing lights after 25 consecutive light exposures without recharging the battery, tip accessibility in the posterior region, and light beam spread from light-curing units. Methods: Irradiance, spectral peak, and radiant exposure were measured with the battery fully charged (Bluephase Style, ESPE Cordless, Elipar S10, Demi Ultra, Valo Cordless, and Radii-Cal) and monitored for 25 light exposures (each lasting 10 seconds). The tip diameter was measured to identify the beam size and the ability of the six light-curing units to irradiate all areas of the lower second molar in the standard output setting. Results: Four curing lights delivered a single peak wavelength from 454 to 462 nm, and two (Bluephase Style and Valo Cordless) delivered multiple emission peaks (at 410 and 458 nm and 400, 450, and 460 nm, respectively). The irradiance and radiant exposure always decreased after 25 exposures by 2% to 8%, depending on the light unit; however, only ESPE Cordless, Valo Cordless, and Radii-Cal presented a statistical difference between the first and the last exposure. The tip diameter ranged from 6.77 mm to 9.40 mm. The Radii-Cal delivered the lowest radiant exposure and irradiance. This light was also unable to access all the teeth with the tip parallel to the occlusal surface of the tooth. Conclusion: Not all of the blue-emitting lights deliver the same emission spectra, and some curing lights delivered a lower irradiance (as much as 8% lower) after the 25th exposure. (AU)

Processo FAPESP: 16/07211-5 - Determinação dos níveis de energia emitidos por unidades de luz utilizadas na fotoativação de compósitos e adesivos odontológicos
Beneficiário:Marcelo Giannini
Modalidade de apoio: Auxílio à Pesquisa - Pesquisador Visitante - Internacional