Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Inter and Intra-Rater Reliability of Short-Term Measurement of Heart Rate Variability on Rest in Diabetic Type 2 Patients

Texto completo
Autor(es):
Bassi, Daniela [1, 2] ; Santos-de-Araujo, Aldair Darlan [3] ; Camargo, Patricia Faria [4] ; Dibai-Filho, Almir Vieira [5] ; da Fonseca, Moyrane Abreu [6] ; Mendes, Renata Goncalves [4] ; Borghi-Silva, Audrey [4]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Ceuma Univ, Postgrad Program Management & Hlth Serv, Sao Luis, MA - Brazil
[2] Univ Ceuma, Dept Fisioterapia, Rua Josue Montello, 1, Jardim Renascenca, BR-65075120 Sao Luis, MA - Brazil
[3] Tiradentes Univ Ctr, Dept Phys Therapy, Maceio, AL - Brazil
[4] Univ Fed Sao Carlos, Dept Phys Therapy, Sao Carlos, SP - Brazil
[5] Univ Fed Maranhao, Dept Phys Educ, Sao Luis, MA - Brazil
[6] Ceuma Univ, Dept Phys Therapy, Sao Luis, MA - Brazil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF MEDICAL SYSTEMS; v. 42, n. 12 DEC 2018.
Citações Web of Science: 1
Resumo

Heart rate variability (HRV) among other methods can be used to assess diabetic cardiac autonomic neuropathy by cardiac intervals were recorded. However, the amount of error depending on this measurement methodology is unclear. To evaluate the intra- and inter-rater reliability to calculate HRV indices, comparing different times and by different trained examiners in patients with type 2 diabetes mellitus (T2DM). Thirty individuals of both genders, aged between 18 and 45years, with T2DM. The RR interval (RRi) were recorded during a 10min period on supine position using a portable heart rate monitor (Polar (R) S810i model). HRV indices were calculated by the software Kubios (R) HRV analysis (version 2.2). Linear (Mean RRi; STD RR; Mean HR; rMSSD; RR Tri; TINN LF; HF; total power) and non-linear (SD1; SD2; DF1; DF2, ApEn and, SampEn) indices were calculated by two examiners with an interval of one week between them. Substantial to excellent was found for reliability of the intra-examiner, with intraclass correlation coefficient (ICC) values ranging from 0.79 to 0.99, standard error of measurement (SEM) between 0.02 and 123.49 (inpercentage: 1.83 and 16.67), and minimum detectable change (MDC) between 0.07 and 342.30. Regarding the inter-examiner reliability, substantial to excellent reliability was found, with ICC values ranging from 0.73 to 0.97, SEM between 0.04 and 178.13 (in percentage: 3.26 and 24.18), and MDC between 0.11 and 493.77. The use of the portable heart rate monitor to measure HRV showed acceptable intra and inter reliability in individuals with T2DM, supporting the use of this method of evaluation in research and clinical practice. (AU)

Processo FAPESP: 09/01842-0 - Análise dos ajustes centrais e metabólicos periféricos durante o exercício físico dinâmico versus resistido em pacientes com DAC: efeitos de um programa de treinamento resistido baseado na determinação do limiar anaeróbio por diferentes metodologias
Beneficiário:Audrey Borghi Silva
Modalidade de apoio: Auxílio à Pesquisa - Jovens Pesquisadores