Objective: The aim of the present study was to evaluate the peripheral temperature rhythmicity and control in individuals with type 1 diabetes mellitus. Methods: Twelve non-obese adults (20-40 years old) with type 1 diabetes mellitus (T1D) and eight control individuals, matched for age and BMI, wore a wrist temperature recorder for 10 consecutive days. Recorded data were aggregated to calculate M10 (ten hours of highest temperature) and L5 (five hours of lowest temperature) of wrist temperature values for both groups. Results: Mean wrist temperature and M10 were not different when comparing the groups. The wrist temperature amplitude was reduced in the T1D group (p=0.039), due to a higher L5 (p=0.038). Discussion: While the higher L5 observed in T1D could be explained by less efficient heat dissipation, the amplitude flattening coincides with that observed in elderly. (AU) | |