Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do SciELO, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Effect of retorque on loosening torque of prosthetic screws under two levels of fit of implant-supported dentures

Texto completo
Autor(es):
Aloísio Oro Spazzin [1] ; Guilherme Elias Pessanha Henrique [2] ; Mauro Antônio de Arruda Nóbilo [3] ; Rafael Leonardo Xediek Consani [4] ; Lourenço Correr-Sobrinho [5] ; Marcelo Ferraz Mesquita [6]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] State University of Campinas. Piracicaba Dental School. Dental Materials Division - Brasil
[2] State University of Campinas. Piracicaba Dental School. Department of Prosthodontics and Periodontics - Brasil
[3] State University of Campinas. Piracicaba Dental School. Department of Prosthodontics and Periodontics - Brasil
[4] State University of Campinas. Piracicaba Dental School. Department of Prosthodontics and Periodontics - Brasil
[5] State University of Campinas. Piracicaba Dental School. Dental Materials Division - Brasil
[6] State University of Campinas. Piracicaba Dental School. Department of Prosthodontics and Periodontics - Brasil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: Brazilian Dental Journal; v. 21, n. 1, p. 12-17, 2010-01-00.
Resumo

This study evaluated the influence of retorque on loosening torque (Lt) of prosthetic screws in implant-supported dentures with different fit levels. Ten mandibular implant-supported dentures were fabricated and then 20 cast models were then prepared using prosthetic structures to create 2 fit levels: passive fit (Pf) and misfit (Mf). Two tightening techniques were also evaluated: initial torque only (T1); and initial torque and retorque after 10 min (T2). Gold or titanium screws were used, resulting in 4 groups to each one: Pf/T1, Pf/T2, Mf/T1, Mf/T2. The Lt was measured 24 h after the tightening torque using digital torque meter. Data were analyzed statistically by two-way ANOVA and Tukey's test (α=0.05), separately for each screw material. For titanium screws, no significant difference (p>0.05) was found between Pf/T1 and Pf/T2, or between Pf/T2 and Mf/T2. However, statistically significant difference (p<0.05) was found between Pf/T1 and Mf/T1, and between Mf/T1 and Mf/T2. Mf reduced the Lt using T1, while and T2 increased the Lt for Mf. Retorque and fit were shown to have no significant influence on the Lt of the gold screws. Retorque application made insignificant the misfit effect on the Lt of the titanium screws, suggesting that this procedure should be performed routinely during the screw tightening in multi-unit dentures. (AU)

Processo FAPESP: 07/55352-8 - Forca de destorque de parafusos proteticos: efeito do desajuste marginal, conferencia do torque e material do parafuso protetico.
Beneficiário:Marcelo Ferraz Mesquita
Modalidade de apoio: Auxílio à Pesquisa - Regular