Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

A novel disposable self-adhesive inked paper device for electrochemical sensing of dopamine and serotonin neurotransmitters and biosensing of glucose

Texto completo
Autor(es):
Orzari, Luiz Otavio [1] ; de Freitas, Rafaela Cristina [1] ; de Araujo Andreotti, Isabela Aparecida [1, 2] ; Gatti, Alexandre [3] ; Janegitz, Bruno Campos [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Fed Sao Carlos, Dept Nat Sci Math & Educ, BR-13600970 Araras, SP - Brazil
[2] Univ Fed Sao Carlos, Ctr Exact Sci & Technol, BR-13560000 Sao Carlos, SP - Brazil
[3] FlackTek Inc, BR-13574290 Sao Carlos, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: BIOSENSORS & BIOELECTRONICS; v. 138, AUG 1 2019.
Citações Web of Science: 2
Resumo

In this work, we detail the progress of a novel electrochemical disposable device, which has a relatively low cost and easy production, with a novel conductive ink, that consists of graphite and automotive varnish mixture, deposited over a self-adhesive paper, granting an easy production with relatively low cost. The electrode surface was characterized by scanning electron microscopy, X-ray powder diffraction and Fourier transforms infrared and Raman, cyclic voltammetry and electrochemical impedance spectroscopies. In addition, the proposed electrode was applied for individual electrochemical determination of dopamine and serotonin. The device achieved a linear response between 30 and 800 mol L-1 and a limit of detection (LOD) of 0.13 mu mol L-1, by square wave voltammetry for dopamine and a linear range from 6.0 to 100 mu mol L-1, with a LOD of 0.39 mol L-1, by differential pulse voltammetry for serotonin. Later, the working electrode was modified with glucose oxidase and dihexadecyl phosphate film in order to obtain a biosensor. At this stage, CV was applied to detect glucose in the range of 1.0-10 mu mol L-1 and LOD of 0.21 mol L-1. By three different techniques and analytes, the sensoring and biosensoring processes presented high reproducibility. The proposed adhesive electrode is easy to prepare, disposable, within non-restrictive nature, which allows an approach of a new device for electrochemical sensing and biosensing. (AU)

Processo FAPESP: 17/21898-6 - Novos dispositivos condutores para aplicação em sensores e biossensores eletroquímicos
Beneficiário:Bruno Campos Janegitz
Linha de fomento: Auxílio à Pesquisa - Regular
Processo FAPESP: 16/12697-4 - Sensores nanoestruturados modificado com grafeno e tapioca para determinação de compostos fenólicos e bases nitrogenadas
Beneficiário:Luiz Otávio Orzari
Linha de fomento: Bolsas no Brasil - Iniciação Científica