Calcium isotope determination in urine samples via the monitoring of (CaF)-Ca-44 and (CaF)-Ca-40 molecules by high-resolution continuum source graphite furnace molecular absorption spectrometry

Texto completo
Autor(es):
Zanatta, Melina B. T. [1] ; Nakadi, V, Flavio ; Resano, Martin [2] ; da Veiga, Marcia A. M. S. [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Dept Chem, FFCLRP, Av Bandeirantes 3900, BR-14040901 Ribeirao Preto, SP - Brazil
[2] Nakadi, Flavio, V, Univ Zaragoza, Dept Analyt Chem, Aragon Inst Engn Res I3A, Pedro Cerbuna 12, Zaragoza 50009 - Spain
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Journal of Analytical Atomic Spectrometry; v. 34, n. 11, p. 2280-2287, NOV 1 2019.
Citações Web of Science: 0
Resumo

This study investigates the possibility of obtaining Ca isotopic information by monitoring the absorption spectrum of a diatomic molecule generated in a graphite furnace using a high-resolution continuum source spectrometer (HR CS GFMAS). The method proposed enables calcium isotopic analysis using CaF as the target species. The difference in wavelength between (CaF)-Ca-40 (maximum at 628.534 nm) and (CaF)-Ca-44 (maximum at 628.191 nm) absorption signals was found to be 337.8 pm, evidencing that both species can be determined simultaneously. The method developed relies on the determination of Ca-40 and Ca-44 concentrations based on calibration functions specific to each isotope and makes use of 12 mu g of F as a molecule forming element without further chemical modifiers. The sensitivity of the method depends on the pH. It increases at pH values close to 2, and decreases until reaching a plateau at pH 6. The characteristic mass found for (CaF)-Ca-40 was 0.11 mu g for solutions with pH 2 and 0.18 mu g for alkaline solutions. The respective limits of detection were 1 and 2 mg L-1. The method was applied to the analysis of three urine samples, spiked with different Ca-40 and Ca-44 amounts. Due to chlorine interference, before the analysis of urine, calcium must be separated from the samples by precipitation with ammonium oxalate. Recovery tests provided results between 95 and 109%, highlighting the potential of the method for Ca-40 and Ca-44 determination in tracer experiments. (AU)