Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Development of miniaturized fluorimetric device for caffeine determination using a smartphone

Texto completo
Autor(es):
Luchiari, Natalia da Costa [1] ; da Silva, Gabrielen Alves [1] ; Marasco Junior, Cesar Augusto [1] ; Feitosa de Lima Gomes, Paulo Clairmont [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] UNESP, Natl Inst Alternat Technol Detect Toxicol Evaluat, Inst Chem, Dept Analyt Chem, POB 355, BR-14800900 Araraquara, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: RSC ADVANCES; v. 9, n. 60, p. 35033-35038, OCT 30 2019.
Citações Web of Science: 0
Resumo

Caffeine is an element that is consumed worldwide. It is present in many products such as beverages, chocolate, coffee, tea, energy drinks and medicines. Portable 3D devices working together with colorimetric and fluorimetric reactions have been able to determine the presence of caffeine in different kinds of samples. Also, digital image-based methods using smartphones have conferred portability and accessibility to miniaturized devices that are innovative and promising options for quick and low cost analyses. This study proposes a miniaturized fluorimetric device to determine caffeine by digital image using a smartphone. The OpenCamera app was used to capture images that were processed using ImageJ software to obtain RGB channels values. The red (R) channel signal intensity was selected as the analytical response. The device developed was applied to determine caffeine in an energy drink and medicines. The method developed presented a linear range from 100 to 600 mg L-1 of caffeine, and quantification (LOQ) and detection (LOD) limits of 100 mg L-1 and 30.0 mg L-1, respectively. The caffeine concentration found in the products analyzed was 328 mg L-1 (+/- 2.5%) for the energy drink, 345 mg L-1 (+/- 15%) for medicine A and 322 mg L-(1) (+/- 7.3%) for medicine B. The proposed device presented important characteristics such as low cost, required small volumes of reagents and samples, quick analysis, portability and suitable to be applied in complex matrices. (AU)

Processo FAPESP: 18/22393-8 - Biocarvão aplicado na remoção de contaminantes emergentes presentes em águas residuárias
Beneficiário:Paulo Clairmont Feitosa de Lima Gomes
Linha de fomento: Auxílio à Pesquisa - Regular
Processo FAPESP: 14/50945-4 - INCT 2014: Instituto Nacional de Tecnologias Alternativas para Detecção, Avaliação Toxicológica e Remoção de Micropoluentes e Radioativos