Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Laser-induced breakdown spectroscopy (LIBS) and wavelength dispersive X-ray fluorescence (WDXRF) data fusion to predict the concentration of K, Mg and P in bean seed samples

Texto completo
Autor(es):
Gamela, Raimundo R. [1] ; Costa, Vinicius C. [2] ; Speranca, Marco A. [1] ; Pereira-Filho, Edenir R. [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, POB 676, BR-13565905 Sao Carlos, SP - Brazil
[2] Fed Univ Alfenas Unifal, Lab Toxicant & Drug Anal LATF, BR-37130000 Alfenas, MG - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Food Research International; v. 132, JUN 2020.
Citações Web of Science: 0
Resumo

The present study aims to develop a fast and simple method for the determination of potassium (K), magnesium (Mg) and phosphor (P) in bean seed samples employing a data fusion strategy in the low-level with laser-induced breakdown spectroscopy (LIBS) and wavelength dispersive X-ray fluorescence (WDXRF) techniques combined with direct solid sample analysis. Univariate and multivariate (multiple linear regression, MLR) calibration and leave-one-out cross validation strategies were evaluated to build the calibration models correlated with reference values obtained by inductively coupled plasma optical emission spectrometry (ICP OES) after microwave-assisted acid digestion. The proposed calibration models for WDXRF and LIBS were tested using 14 samples, where the best results were obtained using the data fusion of both techniques. The standard error of cross validation (SECV) obtained were: 0.12% for K, 0.019% for Mg and 0.10% for P, and the trueness ranged between 89 and 124% for K, 82 to 125% for Mg and 73 to 128% for P. These values showed a good accuracy, precise and robustness of the method and a greater reliability of the results. In addition, the predicted concentrations ranged from 0.97 to 1.55% for K, 0.14 to 0.28% for Mg, and 0.27 to 0.82% for P. (AU)

Processo FAPESP: 16/01513-0 - Combinação de LIBS (Laser-Induced Breakdown Spectroscopy) e ICP OES (Inductively Coupled Plasma Optical Emission Spectrometry) na análise de amostras de resíduo eletrônico (circuito eletrônico e polímeros), alimentos e líquidas de difícil preparação
Beneficiário:Edenir Rodrigues Pereira Filho
Modalidade de apoio: Auxílio à Pesquisa - Regular