SAFIIRA: A heavy-ion multi-purpose irradiation facility in Brazil

Texto completo
Autor(es):
Mostrar menos -
Aguiar, V. A. P. [1] ; Medina, N. H. [1] ; Added, N. [1] ; Macchione, E. L. A. [1] ; Alberton, S. G. [1] ; Leite, A. R. [1] ; Aguirre, F. R. [1] ; Ribas, R. V. [1] ; Perego, C. C. [1] ; Fagundes, L. M. [1] ; Terassi, J. C. [1] ; Brage, J. A. P. [1] ; Simoes, R. F. [1] ; Morais, O. B. [1] ; Almeida, E. A. [1] ; Joaquim, P. M. [1] ; Souza, M. S. [1] ; Cecotte, A. F. M. [1] ; Martins, R. [1] ; Duarte, J. G. [1] ; Scarduelli, V. B. [1] ; Allegro, P. R. P. [1] ; Escudeiro, R. [1] ; Leistenschneider, E. [1] ; Oliveira, R. A. N. [1] ; Servelo, W. A. [1] ; Silva, M. T. [1] ; Sarmento, V. E. [1] ; Carreira, C. A. [1] ; Abreu, J. C. [1] ; Silva, S. C. [1] ; Santos, H. C. [1] ; Rodrigues, C. L. [1] ; Assis, R. F. [1] ; Silva, T. F. [1] ; Tabacniks, M. H. [1] ; Joaquim, A. S. [1] ; Minas, J. H. P. [1] ; Kashinsky, D. [1] ; Guazzelli, M. A. [2] ; Seixas, Jr., L. E. [3] ; Finco, S. [3] ; Benevenutti, F. [4]
Número total de Autores: 43
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Inst Phys, Sao Paulo 05508090 - Brazil
[2] Univ Ctr FEI, Sao Bernardo Do Campo 09850901 - Brazil
[3] Informat Technol Ctr, Campinas 13069901 - Brazil
[4] Univ Fed Rio Grande do Sul, Porto Alegre 91509900, RS - Brazil
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: Review of Scientific Instruments; v. 91, n. 5 MAY 1 2020.
Citações Web of Science: 0
Resumo

This work describes the new facility for applied nuclear physics at the University of Sao Paulo, mainly for irradiation of electronic devices. It is a setup composed of a quadrupole doublet for beam focusing/defocusing plus multiple scattering through gold foils to produce low intensity, large-area, and high-uniformity heavy-ion beams from H-1 to Ag-107. Beam intensities can be easily adjusted from 102particlescm2/s to hundreds of nA for an area as large as 2.0cm2 and uniformity better than 90%. Its irradiation chamber has a high-precision motorized stage, and the system is controlled by a LabView(TM) environment, allowing measurement automation. Design considerations and examples of use are presented. (AU)

Processo FAPESP: 12/03383-5 - Desenvolvimento de metodologia de ensaios de radiação em componentes eletrônicos
Beneficiário:Nilberto Heder Medina
Modalidade de apoio: Auxílio à Pesquisa - Regular